Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo | Número de salidas | Voltaje - Entrada | Voltaje - Salida 1 | Voltaje - Salida 2 | Voltaje - Salida 3 | Voltaje - Salida 4 | Voltaje - Salida 5 | Voltaje - Salida 6 | Corriente - Salida 1 | Corriente - Salida 2 | Corriente - Salida 3 | Corriente - Salida 4 | Corriente - Salida 5 | Corriente - Salida 6 | Potencia (vatios) | Aplicaciones | Voltaje - Aislamiento | Temperatura de funcionamiento | Características | Tipo de montaje | Tamaño/Dimensión |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
101184904NXT-400M-3001-04 |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Open Frame | 3 | 100 ~ 240 VAC | 5V | 15V | - | -15V | - | - | 50 A | 10 A | 5 A | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.00" L x 4.00" W x 1.50" H (177.8mm x 101.6mm x 38.0mm) |
![]() |
101184903NXT-400M-3001-03 |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Open Frame | 3 | 100 ~ 240 VAC | 5V | 12V | - | -15V | - | - | 50 A | 10 A | 5 A | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.00" L x 4.00" W x 1.50" H (177.8mm x 101.6mm x 38.0mm) |
![]() |
101184901NXT-400M-3001-01 |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Open Frame | 3 | 100 ~ 240 VAC | 5V | 12V | - | - | - | - | 50 A | 10 A | 5 A | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.00" L x 4.00" W x 1.50" H (177.8mm x 101.6mm x 38.0mm) |
![]() |
101184902NXT-400M-3001-02 |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Open Frame | 3 | 100 ~ 240 VAC | 5V | 15V | - | -12V | - | - | 50 A | 10 A | 5 A | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.00" L x 4.00" W x 1.50" H (177.8mm x 101.6mm x 38.0mm) |
![]() |
MINT1500A5614E01AC/DC CONVERTER 56V 350W |
2,107 |
|
![]() Tabla de datos |
MINT1500 (500W) | Bulk | Obsolete | Open Frame | 1 | 90 ~ 270 VAC | 56V | - | - | - | - | - | 6.3 A | - | - | - | - | - | 350W (500W Forced Air) | Medical | 4 kV | -10°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Load Sharing, PFC, Remote Sense, Standby Output, Universal Input | Chassis Mount | 7.00" L x 3.30" W x 1.50" H (177.8mm x 83.8mm x 38.2mm) |
![]() |
LU500S24TAC/DC CONVERTER 24V 500W |
4,959 |
|
![]() Tabla de datos |
LU500 (500W) | Bulk | Obsolete | Open Frame | 1 | 90 ~ 305 VAC | 24V | - | - | - | - | - | 20.8 A | - | - | - | - | - | 500W | ITE (Commercial) | 3 kV | -10°C ~ 70°C (With Derating) | DC Input Capable, Universal Input | Chassis Mount | 7.25" L x 4.00" W x 2.20" H (184.2mm x 101.6mm x 55.9mm) |
![]() |
1011625CE-225-4002 |
50 |
|
![]() Tabla de datos |
CE-225 (225W) | Box | Active | Chassis | 4 | 85 ~ 264 VAC | 5V | 3.3V | 12V | -12V | - | - | 25 A | 8 A | 2 A | 2 A | - | - | 225W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.00" L x 4.75" W x 2.00" H (203.2mm x 120.7mm x 50.8mm) |
![]() |
1011630CE-225-4007 |
50 |
|
![]() Tabla de datos |
CE-225 (225W) | Box | Active | Chassis | 4 | 85 ~ 264 VAC | 5V | 12V | 15V | -15V | - | - | 25 A | 8 A | 2 A | 2 A | - | - | 225W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.00" L x 4.75" W x 2.00" H (203.2mm x 120.7mm x 50.8mm) |
![]() |
1011627CE-225-4004 |
50 |
|
![]() Tabla de datos |
CE-225 (225W) | Box | Active | Chassis | 4 | 85 ~ 264 VAC | 5V | -5.2V | 12V | -12V | - | - | 25 A | 8 A | 2 A | 2 A | - | - | 225W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.00" L x 4.75" W x 2.00" H (203.2mm x 120.7mm x 50.8mm) |
![]() |
1011626CE-225-4003 |
50 |
|
![]() Tabla de datos |
CE-225 (225W) | Box | Active | Chassis | 4 | 85 ~ 264 VAC | 5V | 3.3V | 15V | -15V | - | - | 25 A | 8 A | 2 A | 2 A | - | - | 225W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.00" L x 4.75" W x 2.00" H (203.2mm x 120.7mm x 50.8mm) |
![]() |
1011622COCE-225-3001CO |
50 |
|
![]() Tabla de datos |
CE-225 (225W) | Box | Active | Enclosed | 3 | 85 ~ 264 VAC | 5V | 12V | - | -12V | - | - | 25 A | 8 A | 2 A | - | - | - | 225W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.00" L x 4.75" W x 2.17" H (203.2mm x 120.7mm x 55.1mm) |
![]() |
1011623COCE-225-3002CO |
50 |
|
![]() Tabla de datos |
CE-225 (225W) | Box | Active | Enclosed | 3 | 85 ~ 264 VAC | 5V | 15V | - | -15V | - | - | 25 A | 8 A | 2 A | - | - | - | 225W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.00" L x 4.75" W x 2.17" H (203.2mm x 120.7mm x 55.1mm) |
![]() |
101187802CHNXT-400M-2003-02,SB/RE/PF CH |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Chassis | 2 | 100 ~ 240 VAC | 12V | -12 ~ 15V | - | - | - | - | 25 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |
![]() |
101187701CHNXT-400M-2002-01,SB/RE/PF CH |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Chassis | 2 | 100 ~ 240 VAC | 5V | 12 ~ 15V | - | - | - | - | 50 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |
![]() |
101187601CHNXT-400M-2001-01,SB/RE/PF CH |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Chassis | 2 | 100 ~ 240 VAC | 5V | 24 ~ 28V | - | - | - | - | 50 A | 5 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |
![]() |
101187902CHNXT-400M-2004-02,SB/RE/PF CH |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Chassis | 2 | 100 ~ 240 VAC | 15V | -12 ~ 15V | - | - | - | - | 20 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |
![]() |
101187801CHNXT-400M-2003-01,SB/RE/PF CH |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Chassis | 2 | 100 ~ 240 VAC | 12V | -12 ~ 15V | - | - | - | - | 25 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |
![]() |
101187901CHNXT-400M-2004-01,SB/RE/PF CH |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Chassis | 2 | 100 ~ 240 VAC | 15V | -12 ~ 15V | - | - | - | - | 20 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |
![]() |
101187702CHNXT-400M-2002-02,SB/RE/PF CH |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Chassis | 2 | 100 ~ 240 VAC | 5V | 12 ~ 15V | - | - | - | - | 50 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |
![]() |
101187602CHNXT-400M-2001-02,SB/RE/PF CH |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Chassis | 2 | 100 ~ 240 VAC | 5V | 24 ~ 28V | - | - | - | - | 50 A | 5 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |