Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo | Número de salidas | Voltaje - Entrada | Voltaje - Salida 1 | Voltaje - Salida 2 | Voltaje - Salida 3 | Voltaje - Salida 4 | Voltaje - Salida 5 | Voltaje - Salida 6 | Corriente - Salida 1 | Corriente - Salida 2 | Corriente - Salida 3 | Corriente - Salida 4 | Corriente - Salida 5 | Corriente - Salida 6 | Potencia (vatios) | Aplicaciones | Voltaje - Aislamiento | Temperatura de funcionamiento | Características | Tipo de montaje | Tamaño/Dimensión |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
101186902NXT-400M-2004-02,SB/RE |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Open Frame | 2 | 100 ~ 240 VAC | 15V | -12 ~ 15V | - | - | - | - | 20 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.00" L x 4.00" W x 1.50" H (177.8mm x 101.6mm x 38.0mm) |
![]() |
101186602NXT-400M-2001-02,SB/RE |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Open Frame | 2 | 100 ~ 240 VAC | 5V | 24 ~ 28V | - | - | - | - | 50 A | 5 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.00" L x 4.00" W x 1.50" H (177.8mm x 101.6mm x 38.0mm) |
![]() |
101186802NXT-400M-2003-02,SB/RE |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Open Frame | 2 | 100 ~ 240 VAC | 12V | -12 ~ 15V | - | - | - | - | 25 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.00" L x 4.00" W x 1.50" H (177.8mm x 101.6mm x 38.0mm) |
![]() |
101186901NXT-400M-2004-01,SB/RE |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Open Frame | 2 | 100 ~ 240 VAC | 15V | -12 ~ 15V | - | - | - | - | 20 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.00" L x 4.00" W x 1.50" H (177.8mm x 101.6mm x 38.0mm) |
![]() |
101184501CHCONXT-400M-2001-01 CHCO |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 5V | 24 ~ 28V | - | - | - | - | 50 A | 5 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |
![]() |
101184801CHCONXT-400M-2004-01 CHCO |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 15V | -12 ~ 15V | - | - | - | - | 20 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |
![]() |
101184702CHCONXT-400M-2003-02 CHCO |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 12V | -12 ~ 15V | - | - | - | - | 25 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |
![]() |
101184701CHCONXT-400M-2003-01 CHCO |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 12V | -12 ~ 15V | - | - | - | - | 25 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |
![]() |
101184502CHCONXT-400M-2001-02 CHCO |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 5V | 24 ~ 28V | - | - | - | - | 50 A | 5 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |
![]() |
101184601CHCONXT-400M-2002-01 CHCO |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 5V | 12 ~ 15V | - | - | - | - | 50 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |
![]() |
101184602CHCONXT-400M-2002-02 CHCO |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 5V | 12 ~ 15V | - | - | - | - | 50 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |
![]() |
101184802CHCONXT-400M-2004-02 CHCO |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Enclosed | 2 | 100 ~ 240 VAC | 15V | -12 ~ 15V | - | - | - | - | 20 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.10" L x 4.18" W x 1.50" H (180.3mm x 106.2mm x 38.0mm) |
![]() |
1011620COCE-225-2101CO |
50 |
|
![]() Tabla de datos |
CE-225 (225W) | Box | Active | Enclosed | 2 | 85 ~ 264 VAC | 5V | 24V | - | - | - | - | 25 A | 8 A | - | - | - | - | 225W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.00" L x 4.75" W x 2.17" H (203.2mm x 120.7mm x 55.1mm) |
![]() |
1011617COCE-225-2003CO |
50 |
|
![]() Tabla de datos |
CE-225 (225W) | Box | Active | Enclosed | 2 | 85 ~ 264 VAC | 5V | 12V | - | - | - | - | 25 A | 8 A | - | - | - | - | 225W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.00" L x 4.75" W x 2.17" H (203.2mm x 120.7mm x 55.1mm) |
![]() |
1011614COCE-225-2001CO |
50 |
|
![]() Tabla de datos |
CE-225 (225W) | Box | Active | Enclosed | 2 | 85 ~ 264 VAC | 12V | -12V | - | - | - | - | 10 A | 8 A | - | - | - | - | 225W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.00" L x 4.75" W x 2.17" H (203.2mm x 120.7mm x 55.1mm) |
![]() |
1011615COCE-225-2002CO |
50 |
|
![]() Tabla de datos |
CE-225 (225W) | Box | Active | Enclosed | 2 | 85 ~ 264 VAC | 15V | -15V | - | - | - | - | 10 A | 8 A | - | - | - | - | 225W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 8.00" L x 4.75" W x 2.17" H (203.2mm x 120.7mm x 55.1mm) |
![]() |
101187601NXT-400M-2001-01,SB/RE/PF |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Open Frame | 2 | 100 ~ 240 VAC | 5V | 24 ~ 28V | - | - | - | - | 50 A | 5 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.00" L x 4.00" W x 1.50" H (177.8mm x 101.6mm x 38.0mm) |
![]() |
101187602NXT-400M-2001-02,SB/RE/PF |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Open Frame | 2 | 100 ~ 240 VAC | 5V | 24 ~ 28V | - | - | - | - | 50 A | 5 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.00" L x 4.00" W x 1.50" H (177.8mm x 101.6mm x 38.0mm) |
![]() |
101187901NXT-400M-2004-01,SB/RE/PF |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Open Frame | 2 | 100 ~ 240 VAC | 15V | -12 ~ 15V | - | - | - | - | 20 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.00" L x 4.00" W x 1.50" H (177.8mm x 101.6mm x 38.0mm) |
![]() |
101187701NXT-400M-2002-01,SB/RE/PF |
50 |
|
![]() Tabla de datos |
NXT-400 (400W) | Box | Active | Open Frame | 2 | 100 ~ 240 VAC | 5V | 12 ~ 15V | - | - | - | - | 50 A | 10 A | - | - | - | - | 400W | ITE (Commercial), Medical | - | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.00" L x 4.00" W x 1.50" H (177.8mm x 101.6mm x 38.0mm) |