Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo | Tipo de desconexión | Número de posiciones | Número de Niveles | Terminal - Ancho | Estilo de terminación | Corriente - IEC | Voltaje - IEC | Corriente - UL | Voltaje - UL | Calibre o rango del cable - AWG | Calibre o rango del cable - mm² | Características | Color | Tipo de fusible |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
3006302CONN TERM BLK FEED THRU 2-18 AWG |
0 |
|
![]() Tabla de datos |
CLIPLINE UIK | Bulk | Active | Feed Through | - | 2 | 1 | 15.2mm | Screw | 125 A | 800V | 115 A | 600V | 2-18 AWG | 0.75-35mm² | - | Blue | - |
![]() |
2006-1631/1000-5422-CONDUCTOR FUSE TERMINAL BLOCK; |
0 |
|
![]() Tabla de datos |
TOPJOB®S | Box | Active | Disconnect | Fuse | 2 | 1 | 7.5mm | Push In, Spring | 10 A | 800V | 15 A | 65V | 8-20 AWG | 0.5-10mm² | LED | Gray | 1 1/4" x 1/4" |
![]() |
9133151111CONN TERM BLK DISCONN 12-22AWG |
0 |
|
- |
W | Bulk | Obsolete | Disconnect, Feed Through | Fuse, Lever | 4 | 2; Connected | 8.0mm | Screw | - | 300V | - | - | 12-22 AWG | - | - | Beige | 5mm x 20mm, 5mm x 25mm |
![]() |
15288-STCONN TERM BLK DISCONNECT 6-16AWG |
0 |
|
- |
Magnum® 15288 | Bulk | Obsolete | Disconnect | - | 3 | 1 | 43.2mm | Screw | - | - | 65 A | 600V | 6-16 AWG | 1.5-16mm² | - | White | - |
![]() |
280-562/281-4202-CONDUCTOR ACTUATOR TERMINAL BL |
0 |
|
![]() Tabla de datos |
- | Box | Active | Feed Through, Isolated | - | 3 | 2; Connected | 5.0mm | Push In, Spring | 20 A | 400V | - | - | 12-28 AWG | 0.08-2.5mm² | LED, Resistor | Gray | - |
![]() |
1368720000CONN TERM BLK DISCONNECT 8-22AWG |
0 |
|
![]() Tabla de datos |
SAK | Bulk | Active | Disconnect | Fuse, Screw Cap | 2 | 1 | 27.6mm | Screw | 10 A | 500V | - | - | 8-22 AWG | 0.5-16mm² | - | Yellow | E16 |
![]() |
281-613/281-5422-CONDUCTOR FUSE TERMINAL BLOCK; |
0 |
|
![]() Tabla de datos |
- | Box | Active | Disconnect | Fuse | 2 | 1 | 10.0mm | Push In, Spring | 10 A | 800V | - | - | 12-28 AWG | 0.08-4mm² | LED | Gray | 1" x 1/4" |
![]() |
281-613/281-5412-CONDUCTOR FUSE TERMINAL BLOCK; |
0 |
|
![]() Tabla de datos |
- | Box | Active | Disconnect | Fuse | 2 | 1 | 10.0mm | Push In, Spring | 10 A | 800V | - | - | 12-28 AWG | 0.08-4mm² | LED | Gray | 1" x 1/4" |
![]() |
281-635/281-489COMPONENT TERMINAL BLOCK; DOUBLE |
0 |
|
![]() Tabla de datos |
- | Box | Active | Disconnect, Feed Through | - | 4 | 2 | 6.0mm | Push In, Spring | 500 mA | - | - | - | 12-28 AWG | 0.08-4mm² | Diode | Gray | - |
![]() |
281-622/281-5412-CONDUCTOR FUSE TERMINAL BLOCK; |
0 |
|
![]() Tabla de datos |
- | Box | Active | Disconnect | Fuse | 2 | 1 | 8.0mm | Push In, Spring | 10 A | 800V | - | - | 12-28 AWG | 0.08-4mm² | Neon Lamp | Gray | 5mm x 30mm |
![]() |
281-612/281-5412-CONDUCTOR FUSE TERMINAL BLOCK; |
0 |
|
![]() Tabla de datos |
- | Box | Active | Disconnect | Fuse | 2 | 1 | 8.0mm | Push In, Spring | 10 A | 800V | - | - | 12-28 AWG | 0.08-4mm² | LED | Gray | - |
![]() |
280-502/281-613COMPONENT TERMINAL BLOCK; DOUBLE |
0 |
|
![]() Tabla de datos |
- | Box | Active | Feed Through | - | 2 | 1 | 5.0mm | Push In, Spring | - | - | 20 A | 24V | 14-28 AWG | 0.08-2.5mm² | Varistor | Gray | - |
![]() |
280-502/281-612COMPONENT TERMINAL BLOCK; DOUBLE |
0 |
|
![]() Tabla de datos |
- | Box | Active | Feed Through | - | 2 | 1 | 5.0mm | Push In, Spring | - | - | 20 A | 110V | 14-28 AWG | 0.08-2.5mm² | Varistor | Gray | - |
![]() |
280-502/281-610COMPONENT TERMINAL BLOCK; DOUBLE |
0 |
|
![]() Tabla de datos |
- | Box | Active | Feed Through | - | 2 | 1 | 5.0mm | Push In, Spring | - | - | 20 A | 48V | 14-28 AWG | 0.08-2.5mm² | Varistor | Gray | - |
![]() |
0582460000CONN TERM BLK FEED THRU 2-12 AWG |
0 |
|
![]() Tabla de datos |
SAK | Bulk | Active | Feed Through | - | 2 | 1 | 18.0mm | Screw | 125 A | 800V | 105 A | 600V | 2-12 AWG | 2.5-35mm² | - | Beige | - |
![]() |
3211868PT 6-HESILED 60 (6 3X32) |
0 |
|
![]() Tabla de datos |
CLIPLINE PT | Bulk | Active | Disconnect | Fuse, Lever | 2 | 1 | 8.2mm | Push In | 10 A | 60V | 5 A | 600V | 8-20 AWG | 0.5-10mm² | Diode | Black | 6.3mm x 32mm |
![]() |
2006-1631/1099-5422-CONDUCTOR FUSE TERMINAL BLOCK; |
0 |
|
![]() Tabla de datos |
TOPJOB®S | Box | Active | Disconnect | Fuse | 2 | 1 | 10.4mm | Push In, Spring | 10 A | 800V | 15 A | 65V | 8-20 AWG | 0.5-10mm² | LED | Gray | 1 1/4" x 1/4" |
![]() |
2006-1631/1099-8362-CONDUCTOR FUSE TERMINAL BLOCK; |
0 |
|
![]() Tabla de datos |
TOPJOB®S | Box | Active | Disconnect | Fuse | 2 | 1 | 10.4mm | Push In, Spring | 10 A | 800V | 15 A | 230V | 8-20 AWG | 0.5-10mm² | LED | Gray | 1 1/4" x 1/4" |
![]() |
NSYTRV44DPESCREW TERMINAL, 2 LEVEL GROUND, |
0 |
|
![]() Tabla de datos |
Linergy TR | Box | Active | Ground, Earth | - | 4 | 2; Connected | 6.2mm | Screw | - | - | - | - | - | 0.14-6mm² | - | Green, Yellow | - |
![]() |
KTB2-025TERM BLK SCREW 20PCS BUNDLE |
4 |
|
![]() Tabla de datos |
KTB2/3 | Bulk | Active | Feed Through | - | 2 | 1 | 11.0mm | Screw | - | - | 25 A | 600V | - | - | - | Black | - |