Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Función | Voltaje - Suministro | Rango de disparo | Tiempo de retardo | Tipo de montaje | Estilo de terminación | Características | Temperatura de funcionamiento |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SE-330-23-00GRND RES RELAY ETHERNET-DC SUP |
4,472 |
|
![]() Tabla de datos |
SE-330 | Bulk | Active | Ground Fault | 48VDC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330-21-00GRND RES RELAY DEVICENET DC SUP |
4,939 |
|
![]() Tabla de datos |
SE-330 | Bulk | Active | Ground Fault | 48VDC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330-21-01NGR MONITOR NC 48-VDC D-NET |
3,278 |
|
![]() Tabla de datos |
SE-330 | Bulk | Active | Ground Fault | 48VDC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330-23-01NGR MONITOR NC 48-VDC ETHERNET |
2,577 |
|
![]() Tabla de datos |
SE-330 | Bulk | Active | Ground Fault | 48VDC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330AU-23-01NEUTRAL-EARTHING-RES MON 48VDC E |
4,049 |
|
![]() Tabla de datos |
SE-330AU | Bulk | Active | Ground Fault | 120 ~ 240VAC/DC | 0.125 ~ 30A | 0.1 ~ 0.5s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-135-03GFGC MONITOR ETHERNET |
4,513 |
|
![]() Tabla de datos |
SE-135 | Bulk | Active | Ground Fault | 120 ~ 240VAC/DC | - | 0.1 ~ 2.5s | Panel Mount | Screw Terminal | CT Loop Monitoring, Harmonic Filtering, Manual Reset, Test Button | -40°C ~ 60°C |
![]() |
SE-330AU-01-00NEUTRAL-EARTHING-RESISTOR MON. D |
2,417 |
|
![]() Tabla de datos |
SE-330AU | Bulk | Active | Ground Fault | 48VDC | 0.125 ~ 30A | 0.1 ~ 0.5s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330AU-01-01NEUTRAL-EARTHING-RES MON DEVICEN |
2,549 |
|
![]() Tabla de datos |
SE-330AU | Bulk | Active | Ground Fault | 48VDC | 0.125 ~ 30A | 0.1 ~ 0.5s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330HV-21-00NGR MONITOR HV LVPS DEVICENET |
3,495 |
|
![]() Tabla de datos |
SE-330HV | Bulk | Active | Ground Fault | 48VDC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330HV-21-01NGR MONITOR HV LVPS DEVICENET NC |
4,826 |
|
![]() Tabla de datos |
SE-330HV | Bulk | Active | Ground Fault | 48VDC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330HV-23-00NGR MONITOR HV LVPS ETHERNET |
2,645 |
|
![]() Tabla de datos |
SE-330HV | Bulk | Active | Ground Fault | 48VDC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330HV-23-01NGR MONITOR HV LVPS ETHERNET NC |
2,749 |
|
![]() Tabla de datos |
SE-330HV | Bulk | Active | Ground Fault | 48VDC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330-06-00NGR MON UNIV E-NET DUAL RJ45 618 |
3,811 |
|
![]() Tabla de datos |
SE-330 | Bulk | Active | Ground Fault | 120/240VAC/DC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330-06-01NGR MON UNIV DUAL RJ45 61850 K4 |
2,804 |
|
![]() Tabla de datos |
SE-330 | Bulk | Active | Ground Fault | 120/240VAC/DC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330-07-01NGR MON UNIV SC FIBER RJ45 61850 |
3,591 |
|
![]() Tabla de datos |
SE-330 | Bulk | Active | Ground Fault | 120/240VAC/DC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330-08-00NGR MON UNIV DUAL SC FIBER 61850 |
4,541 |
|
![]() Tabla de datos |
SE-330 | Bulk | Active | Ground Fault | 120/240VAC/DC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330-08-01NGR MON UNIV DUAL SC FIBER 61850 |
3,932 |
|
![]() Tabla de datos |
SE-330 | Bulk | Active | Ground Fault | 120/240VAC/DC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330HV-01-00NGR MONITOR HV DEVICENET |
4,038 |
|
![]() Tabla de datos |
SE-330HV | Bulk | Active | Ground Fault | 120 ~ 240VAC/DC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330HV-01-01NGR MONITOR HV DEVICENET NC K4 |
3,394 |
|
![]() Tabla de datos |
SE-330HV | Bulk | Active | Ground Fault | 120 ~ 240VAC/DC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |
![]() |
SE-330HV-03-00NGR MONITOR HV ETHERNET |
2,855 |
|
![]() Tabla de datos |
SE-330HV | Bulk | Active | Ground Fault | 120 ~ 240VAC/DC | 20 ~ 10000VAC | 0.1 ~ 10s | Panel Mount | Screw Terminal | Harmonic Filtering, Manual Reset | -40°C ~ 60°C |