Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Paquete/Caja | Embalaje | Estado del producto | Tipo | Número de salidas | Voltaje: entrada (mín.) | Voltaje: entrada (máx.) | Voltaje - Salida 1 | Voltaje - Salida 2 | Voltaje - Salida 3 | Voltaje - Salida 4 | Corriente - Salida (máx.) | Potencia (vatios) | Voltaje - Aislamiento | Aplicaciones | Características | Temperatura de funcionamiento | Eficiencia | Grado | Calificación | Tipo de montaje | Proveedor Dispositivo Paquete | Funciones de control | Organismo de aprobación | Número estándar |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
PXG-M20-24WD12DC DC CONVERTER +/-12V 20W TDK-Lambda |
20 |
|
![]() Tabla de datos |
PXG-M (20W) | 6-DIP Module | Tube | Active | Isolated Module | 2 | 9V | 36V | 12V | -12V | - | - | 833mA, 833mA | 20 W | 5 kV | ITE (Commercial), Medical | Adjustable Output | -40°C ~ 105°C (With Derating) | 88.5% | - | - | Through Hole | - | - | CE | - |
![]() |
PXG-M20-48WD15DC DC CONVERTER +/-15V 20W TDK-Lambda |
20 |
|
![]() Tabla de datos |
PXG-M (20W) | 6-DIP Module | Tube | Active | Isolated Module | 2 | 18V | 75V | 15V | -15V | - | - | 677mA, 677mA | 20 W | 5 kV | ITE (Commercial), Medical | Adjustable Output | -40°C ~ 105°C (With Derating) | 89% | - | - | Through Hole | - | - | CE | - |
![]() |
PXG-M20-48WD12DC DC CONVERTER +/-12V 20W TDK-Lambda |
11 |
|
![]() Tabla de datos |
PXG-M (20W) | 6-DIP Module | Tube | Active | Isolated Module | 2 | 18V | 75V | 12V | -12V | - | - | 833mA, 833mA | 20 W | 5 kV | ITE (Commercial), Medical | Adjustable Output | -40°C ~ 105°C (With Derating) | 88.5% | - | - | Through Hole | - | - | CE | - |
![]() |
PXG-M20-24WD05DC DC CONVERTER +/-5V 20W TDK-Lambda |
8 |
|
![]() Tabla de datos |
PXG-M (20W) | 6-DIP Module | Tube | Active | Isolated Module | 2 | 9V | 36V | 5V | -5V | - | - | 2A, 2A | 20 W | 5 kV | ITE (Commercial), Medical | Adjustable Output | -40°C ~ 105°C (With Derating) | 86% | - | - | Through Hole | - | - | CE | - |
![]() |
PXD40-24WD12DC DC CONVERTER +/-12V 40W TDK-Lambda |
15 |
|
![]() Tabla de datos |
PXD40 (40W) | 6-DIP Module | Tube | Active | Isolated Module | 2 | 9V | 36V | 12V | -12V | - | - | 1.666A, 1.666A | 40 W | 1.6 kV | ITE (Commercial) | Adjustable Output, Remote On/Off, Remote Sense | -40°C ~ 105°C (With Derating) | 91% | - | - | Through Hole | - | Enable, Active High | CE, UKCA | 62368-1 |
![]() |
CC30-2415SFP-EDC DC CONVERTER 15V 30W TDK-Lambda |
6 |
|
![]() Tabla de datos |
CC-P-E (30W) | 20-DIP Module, 17 Leads | Tray | Active | Isolated Module | 1 | 18V | 36V | 15V | - | - | - | 2A | 30 W | 1 kV | ITE (Commercial) | - | -40°C ~ 85°C | 89% | - | - | Through Hole | - | Enable, Active Low | - | - |
![]() |
IQL24040A050V-001-RDC DC CONVERTER 5V TDK-Lambda |
18 |
|
![]() Tabla de datos |
iQL (200W) | 8-DIP Module, 1/4 Brick | Tray | Active | Intermediate Bus Converter | 1 | 20V | 36V | 5V | - | - | - | 40A | - | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OVP | -40°C ~ 119°C | 91% | - | - | Through Hole | - | Enable, Active Low | - | - |
|
IQL48045A050V-009-RDC DC CONVERTER 5V 225W TDK-Lambda |
14 |
|
![]() Tabla de datos |
iQL (225W) | 8-DIP Module, 1/4 Brick | Tray | Active | Intermediate Bus Converter | 1 | 36V | 75V | 5V | - | - | - | 45A | 225 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OVP | -40°C ~ 119°C | 91% | - | - | Through Hole | - | Enable, Active Low | - | - |
![]() |
PXD-M30-48WS15DC DC CONVERTER 15V 30W TDK-Lambda |
16 |
|
![]() Tabla de datos |
PXD-M (30W) | 6-DIP Module | Tube | Active | Isolated Module | 1 | 18V | 75V | 15V | - | - | - | 2A | 30 W | 5 kV | ITE (Commercial), Medical | Adjustable Output | -40°C ~ 105°C (With Derating) | 90% | - | - | Through Hole | - | - | CE | - |
![]() |
PXD-M30-24WD15DC DC CONVERTER +/-15V 30W TDK-Lambda |
16 |
|
![]() Tabla de datos |
PXD-M (30W) | 6-DIP Module | Tube | Active | Isolated Module | 2 | 9V | 36V | 15V | -15V | - | - | 1A, 1A | 30 W | 5 kV | ITE (Commercial), Medical | Adjustable Output | -40°C ~ 105°C (With Derating) | 90% | - | - | Through Hole | - | - | CE | - |