Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo de filtro | Configuración | Voltaje - CC nominal | Voltaje - CA nominal | Voltaje - CA nominal (fase a tierra/neutro) | Voltaje - CA nominal (fase a fase) | Corriente | Frecuencia - Funcionamiento | Aplicaciones | Organismo de aprobación | Temperatura de funcionamiento | Tipo de montaje | Estilo de terminación | Inductancia |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
NBH-30-101LINE FILTER 250VAC/VDC 30A CHASS |
0 |
|
![]() Tabla de datos |
NBH | Box | Active | Single Phase | Two Stage | 250V | 250V | 250 V | - | 30 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
NBH-30-102LINE FILTER 250VAC/VDC 30A CHASS |
0 |
|
![]() Tabla de datos |
NBH | Box | Active | Single Phase | Two Stage | 250V | 250V | 250 V | - | 30 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
NBH-30-221LINE FILTER 250VAC/VDC 30A CHASS |
0 |
|
![]() Tabla de datos |
NBH | Box | Active | Single Phase | Two Stage | 250V | 250V | 250 V | - | 30 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
NBH-30-331LINE FILTER 250VAC/VDC 30A CHASS |
0 |
|
![]() Tabla de datos |
NBH | Box | Active | Single Phase | Two Stage | 250V | 250V | 250 V | - | 30 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
NBH-30-471LINE FILTER 250VAC/VDC 30A CHASS |
0 |
|
![]() Tabla de datos |
NBH | Box | Active | Single Phase | Two Stage | 250V | 250V | 250 V | - | 30 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
FN2070B-16-08LINE FILTER 250VAC/VDC 16A CHASS |
0 |
|
![]() Tabla de datos |
FN 2070 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 16 A | DC ~ 400Hz | Medical | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 1mH |
|
10TDPS6(D)LINE FILTER 10A DIN RAIL |
0 |
|
![]() Tabla de datos |
TDP | Box | Active | Three Phase (Delta) | Single Stage | - | - | - | - | 10 A | - | General Purpose | cURus, ENEC | - | DIN Rail | Terminal Block | 10mH |
|
6609973-4LINE FILTER 6A CHASSIS MOUNT |
0 |
|
![]() Tabla de datos |
IK | Bulk | Active | Single Phase | Single Stage | - | - | 480 V | 500 V | 6 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | - |
|
15EHT6LINE FILTER 250VAC 15A CHASS MNT |
0 |
|
![]() Tabla de datos |
HT | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 15 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 5.07mH |
|
RSAN-2040LINE FILTER 250VAC/VDC 40A CHASS |
0 |
|
![]() Tabla de datos |
RSAN | Bulk | Active | Single Phase | Single Stage | 250V | 250V | - | - | 40 A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
K10-10ELINE FILTER, 250VAC, 10A, CHASSI |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
6KEMS10BFPDLINE FILTER 520VAC 6A CHASS MNT |
0 |
|
- |
KEM | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 6 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
16TDPS6(D)LINE FILTER 16A DIN RAIL |
0 |
|
![]() Tabla de datos |
TDP | Box | Active | Three Phase (Delta) | Single Stage | - | - | - | - | 16 A | - | General Purpose | cURus, ENEC | - | DIN Rail | Terminal Block | 4.3mH |
|
20TDPS6(D)LINE FILTER 20A DIN RAIL |
0 |
|
![]() Tabla de datos |
TDP | Box | Active | Three Phase (Delta) | Single Stage | - | - | - | - | 20 A | - | General Purpose | cURus, ENEC | - | DIN Rail | Terminal Block | 2.5mH |
![]() |
20TDPS6ELINE FILTER 20A CHASSIS MOUNT |
0 |
|
![]() Tabla de datos |
TDP | Box | Active | Three Phase (Delta) | Single Stage | - | - | - | - | 20 A | - | General Purpose | cURus, ENEC | - | Chassis Mount | Terminal Block | 14.8mH |
|
30TDPS6(D)LINE FILTER 30A DIN RAIL |
0 |
|
![]() Tabla de datos |
TDP | Box | Active | Three Phase (Delta) | Single Stage | - | - | - | - | 30 A | - | General Purpose | cURus, ENEC | - | DIN Rail | Terminal Block | 1.2mH |
![]() |
FN2080B-16-06LINE FILTER 110V/250VAC 16A CHAS |
0 |
|
![]() Tabla de datos |
FN 2080 | Tray | Active | Single Phase | Two Stage | - | 110V, 250V | - | - | 16 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 2.8mH |
![]() |
MBS-1205-22LINE FILTER 250VAC/VDC 5A CHASS |
0 |
|
![]() Tabla de datos |
MBS | Bulk | Obsolete | Single Phase | Single Stage | 250V | 250V | - | - | 5 A | - | General Purpose | CSA, UL, VDE | -25°C ~ 85°C | Chassis Mount | Threaded Post (M4) | - |
![]() |
FN2070B-25-08LINE FILTER 250VAC/VDC 25A CHASS |
0 |
|
![]() Tabla de datos |
FN 2070 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 25 A | DC ~ 400Hz | Medical | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 2.2mH |
![]() |
F20-4EMI FILTER, SINGLE PHASE, 20A |
0 |
|
- |