Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo de filtro | Configuración | Voltaje - CC nominal | Voltaje - CA nominal | Voltaje - CA nominal (fase a tierra/neutro) | Voltaje - CA nominal (fase a fase) | Corriente | Frecuencia - Funcionamiento | Aplicaciones | Organismo de aprobación | Temperatura de funcionamiento | Tipo de montaje | Estilo de terminación | Inductancia |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
NAM-10-331LINE FILTER 250VAC/VDC 10A CHASS |
0 |
|
![]() Tabla de datos |
NAM | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 10 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
NAM-10-471LINE FILTER 250VAC/VDC 10A CHASS |
0 |
|
![]() Tabla de datos |
NAM | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 10 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
1KEBS1AFPDDMLINE FILTER 440VAC 1A CHASS MNT |
0 |
|
![]() Tabla de datos |
KEB | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 1 A | 50 ~ 60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
![]() |
1KESS1AFPWLINE FILTER 440VAC 1A CHASS MNT |
0 |
|
![]() Tabla de datos |
KES | Box | Active | Three Phase (Wye) | Single Stage | - | 440V | - | - | 1 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
![]() |
10DRPS4(D)LINE FILTER 250VAC 10A CHASS MNT |
0 |
|
![]() Tabla de datos |
DRP | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 10 A | 50/60Hz | General Purpose | cURus, ENEC | - | Chassis Mount | Terminal Block | 1.7mH |
![]() |
FN2090B-4-07LINE FILTER 250VAC/VDC 4A CHASS |
0 |
|
![]() Tabla de datos |
FN 2090 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 4 A | 50 ~ 60Hz | Medical | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 14mH |
![]() |
FN2090BZ-4-06LINE FILTER 250VAC/VDC 4A CHASS |
0 |
|
![]() Tabla de datos |
FN 2090 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 4 A | 50 ~ 60Hz | Medical | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 14mH |
![]() |
FN2090-6-08LINE FILTER 250VAC/VDC 6A CHASS |
0 |
|
![]() Tabla de datos |
FN 2090 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 6 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 8mH |
![]() |
ESP-16-000LINE FILTER 250VAC/VDC 16A CHASS |
2 |
|
![]() Tabla de datos |
ESP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
ESP-16-101LINE FILTER 250VAC/VDC 16A CHASS |
2 |
|
![]() Tabla de datos |
ESP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
ESP-16-102LINE FILTER 250VAC/VDC 16A CHASS |
2 |
|
![]() Tabla de datos |
ESP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
ESP-16-221LINE FILTER 250VAC/VDC 16A CHASS |
2 |
|
![]() Tabla de datos |
ESP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
ESP-16-222LINE FILTER 250VAC/VDC 16A CHASS |
2 |
|
![]() Tabla de datos |
ESP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
ESP-16-331LINE FILTER 250VAC/VDC 16A CHASS |
2 |
|
![]() Tabla de datos |
ESP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
ESP-16-332LINE FILTER 250VAC/VDC 16A CHASS |
2 |
|
![]() Tabla de datos |
ESP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
ESP-16-471LINE FILTER 250VAC/VDC 16A CHASS |
2 |
|
![]() Tabla de datos |
ESP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
ESP-16-681LINE FILTER 250VAC/VDC 16A CHASS |
2 |
|
![]() Tabla de datos |
ESP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
EAC-20-102-DLINE FILTER 250VAC/VDC 20A DIN |
0 |
|
![]() Tabla de datos |
EAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
![]() |
EAC-20-222-DLINE FILTER 250VAC/VDC 20A DIN |
0 |
|
![]() Tabla de datos |
EAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
![]() |
EAC-20-332-DLINE FILTER 250VAC/VDC 20A DIN |
0 |
|
![]() Tabla de datos |
EAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |