Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo de filtro | Configuración | Voltaje - CC nominal | Voltaje - CA nominal | Voltaje - CA nominal (fase a tierra/neutro) | Voltaje - CA nominal (fase a fase) | Corriente | Frecuencia - Funcionamiento | Aplicaciones | Organismo de aprobación | Temperatura de funcionamiento | Tipo de montaje | Estilo de terminación | Inductancia |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
FMAD-395A-1612LINE FILTER 300V/520VAC 16A CHAS SCHURTER Inc. |
3 |
|
![]() Tabla de datos |
FMAD | Box | Active | Three Phase (Wye) | Single Stage | - | 300V, 520V | - | - | 16 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
![]() |
FMAD-345B-3612LINE FILTER 300V/520VAC 36A CHAS SCHURTER Inc. |
3 |
|
![]() Tabla de datos |
FMAD | Box | Active | Three Phase (Wye) | Single Stage | - | 300V, 520V | - | - | 36 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
![]() |
5500.2607.03LINE FILTER 125V/250VAC 30A CHAS SCHURTER Inc. |
2 |
|
![]() Tabla de datos |
FMBB NEO | Bulk | Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 30 A | - | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 600µH |
![]() |
FMBC-345B-3614LINE FILTER 760VAC 25A CHASS MNT SCHURTER Inc. |
2 |
|
![]() Tabla de datos |
FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | 760V | - | - | 25 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
![]() |
FMBC-395A-2512LINE FILTER 520VAC 25A CHASS MNT SCHURTER Inc. |
5 |
|
![]() Tabla de datos |
FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | 520V | - | - | 25 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
![]() |
FMBC-345B-5014LINE FILTER 760VAC 50A CHASS MNT SCHURTER Inc. |
5 |
|
![]() Tabla de datos |
FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | 760V | - | - | 50 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
![]() |
FMBC-395A-2514LINE FILTER 760VAC 25A CHASS MNT SCHURTER Inc. |
3 |
|
![]() Tabla de datos |
FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | 760V | - | - | 25 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
![]() |
FMBD-345A-2512LINE FILTER 520VAC 25A CHASS MNT SCHURTER Inc. |
4 |
|
![]() Tabla de datos |
FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | 520V | - | - | 25 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
![]() |
FMBC-395A-1614LINE FILTER 760VAC 16A CHASS MNT SCHURTER Inc. |
3 |
|
![]() Tabla de datos |
FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | 760V | - | - | 16 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
![]() |
FMBC-345A-1614LINE FILTER 760VAC 16A CHASS MNT SCHURTER Inc. |
4 |
|
![]() Tabla de datos |
FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | 760V | - | - | 16 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |