Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo | Función | Tipo de actuador | Presión de funcionamiento | Diámetro del orificio | Tipo de fluido | Método de conexión | Para usar con/productos relacionados | Tipo de montaje | Características |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
VMPAL-AP-20-T1-RVSUB-BASE |
0 |
|
- |
- | Bulk | Active | Sub-Base | - | - | -13.05 ~ 145 PSI (-0.9 ~ 10 bar) | - | Air | Threaded | Control Valve | Sub-Base Mount | - |
![]() |
VMPAL-AP-20-T35-RVSUB-BASE |
0 |
|
- |
- | Bulk | Active | Sub-Base | - | - | -13.05 ~ 145 PSI (-0.9 ~ 10 bar) | - | Air | Threaded | Control Valve | Sub-Base Mount | - |
![]() |
VMPAL-AP-20-RVSUB-BASE |
0 |
|
- |
- | Bulk | Active | Sub-Base | - | - | -13.05 ~ 145 PSI (-0.9 ~ 10 bar) | - | Air | Threaded | Control Valve | Sub-Base Mount | - |
![]() |
VOVK-BT6-M32C-MN-5H5ZP-FBSOLENOID VALVE |
0 |
|
- |
VOVK | Bulk | Active | Solenoid Valve | 3/2 Normally Closed | - | -14.5 ~ 102 PSI (-1 ~ 7 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 12VDC |
![]() |
VOVK-BT6-M32C-MN-1H5ZP-FBSOLENOID VALVE |
0 |
|
- |
VOVK | Bulk | Active | Solenoid Valve | 3/2 Normally Closed | - | -14.5 ~ 102 PSI (-1 ~ 7 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |
![]() |
GRLA-1/4-QB-3/16-UONE-WAY FLOW CONTROL VALVE |
0 |
|
- |
GRLA | Bulk | Active | Flow Restrictor, Adjustable | One-Way | - | -14 ~ 116 PSI (-1 ~ 8 bar) | - | Air | Threaded 1/4" NPT | Control Valve | Free Hanging (In-Line) | - |
![]() |
VZBM-1/4-RP-40-D-2-F03-B2B3BALL VALVE |
0 |
|
![]() Tabla de datos |
VZBM | Bulk | Active | Ball Valve | 2/2 | - | - | - | Air, Inert Gas, Liquid | Threaded 1/4" Rp | Control Valve | Free Hanging (In-Line) | - |
![]() |
VZBM-3/8-RP-40-D-2-F03-B2B3BALL VALVE |
0 |
|
![]() Tabla de datos |
VZBM | Bulk | Active | Ball Valve | 2/2 | - | - | - | Air, Inert Gas, Liquid | Threaded 3/8" Rp | Control Valve | Free Hanging (In-Line) | - |
![]() |
QH-3/8BALL VALVE |
0 |
|
- |
QH | Bulk | Active | Ball Valve | 2/2 | - | - | - | Air, Inert Gas, Liquid | Threaded G3/8" | Control Valve | Free Hanging (In-Line) | - |
![]() |
HA-10-32-UNF-QSM-5/32-UCHECK VALVE |
0 |
|
- |
HA | Bulk | Active | Non-Return Valve (Check Valve) | - | - | 14.5 ~ 145 PSI (1 ~ 10 bar) | - | Air | Threaded | Control Valve | Free Hanging (In-Line) | - |
![]() |
HB-M5-QS-4CHECK VALVE |
0 |
|
- |
HB | Bulk | Active | Non-Return Valve (Check Valve) | - | - | 14.5 ~ 145 PSI (1 ~ 10 bar) | - | Air | Threaded | Control Valve | Free Hanging (In-Line) | - |
![]() |
HA-M5-QS-4CHECK VALVE |
0 |
|
- |
HA | Bulk | Active | Non-Return Valve (Check Valve) | - | - | 14.5 ~ 145 PSI (1 ~ 10 bar) | - | Air | Threaded | Control Valve | Free Hanging (In-Line) | - |
|
DSP-12090SOLENOID PMP 900CC/MIN FREE HANG |
0 |
|
![]() Tabla de datos |
DSP | Box | Active | Solenoid Pump | - | - | 0 ~ 175 PSI (0 ~ 12.1 bar) | - | Liquid | Barbed Connection for Tubing 7mm Dia., Threaded 1/8" BSP | - | Free Hanging (In-Line) | Integrated Diode, Supply Voltage 110VAC |
![]() |
VSCS-B-M32-MH-WA-1AC1-8SOLENOID VALVE |
0 |
|
![]() Tabla de datos |
VSCS | Bulk | Active | Solenoid Valve | 3/2 Normally Closed | - | 22 ~ 116 PSI (1.5 ~ 8 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |
![]() |
VSCS-B-M32-MH-WA-2AC1-8SOLENOID VALVE |
0 |
|
![]() Tabla de datos |
VSCS | Bulk | Active | Solenoid Valve | 3/2 Normally Closed | - | 22 ~ 116 PSI (1.5 ~ 8 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 110VAC |
![]() |
VSCS-B-M32-MH-WA-5C1-8SOLENOID VALVE |
0 |
|
![]() Tabla de datos |
VSCS | Bulk | Active | Solenoid Valve | 3/2 Normally Closed | - | 22 ~ 116 PSI (1.5 ~ 8 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 12VDC |
![]() |
VSCS-B-M32-MH-WA-3AC1-8SOLENOID VALVE |
0 |
|
![]() Tabla de datos |
VSCS | Bulk | Active | Solenoid Valve | 3/2 Normally Closed | - | 22 ~ 116 PSI (1.5 ~ 8 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 230VAC |
![]() |
GRO-QS-3THROTTLE VALVE |
0 |
|
- |
GRO | Bulk | Active | Flow Restrictor, Adjustable | - | - | 0 ~ 145 PSI (0 ~ 10 bar) | - | Air | Threaded | Control Valve | Free Hanging (In-Line) | - |
![]() |
VZBM-1/2-RP-25-D-2-F03-B2B3BALL VALVE |
0 |
|
![]() Tabla de datos |
VZBM | Bulk | Active | Ball Valve | 2/2 | - | - | - | Air, Inert Gas, Liquid | Threaded 1/2" Rp | Control Valve | Free Hanging (In-Line) | - |
![]() |
HE-2-QS-10SHUT-OFF VALVE |
0 |
|
- |
HE | Bulk | Active | Solenoid Valve | 2/2 | - | -1 ~ 145 PSI (-0.1 ~ 10 bar) | - | Air | Push-In Connection for Tubing 24/64" (10.00mm) Dia | Solenoid Valve | Free Hanging (In-Line) | - |