Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo | Función | Tipo de actuador | Presión de funcionamiento | Diámetro del orificio | Tipo de fluido | Método de conexión | Para usar con/productos relacionados | Tipo de montaje | Características |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
JH-5-1/8PNEUMATIC VALVE |
4,156 |
|
- |
JH | Bulk | Active | Control Valve | 5/2 | - | 0 ~ 145 PSI (0 ~ 10 bar) | - | Air | Threaded G1/8" | Control Valve | Chassis Mount | - |
![]() |
JH-5-1/8-NPTPNEUMATIC VALVE |
4,145 |
|
- |
JH | Bulk | Active | Control Valve | 5/2 | - | 0 ~ 145 PSI (0 ~ 10 bar) | - | Air | Threaded 1/8" NPT | Control Valve | Chassis Mount | - |
![]() |
VMPA14-M1HF-E-PISOLENOID VALVE |
3,254 |
|
- |
VMPA | Bulk | Active | Solenoid Valve | 5/3 | - | -1 ~ 145 PSI (-0.1 ~ 10 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |
![]() |
VMPA14-M1HF-G-PISOLENOID VALVE |
4,840 |
|
- |
VMPA | Bulk | Active | Solenoid Valve | 5/3 Normally Closed | - | -1 ~ 145 PSI (-0.1 ~ 10 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |
![]() |
VMPA14-M1HF-B-PISOLENOID VALVE |
3,433 |
|
- |
VMPA | Bulk | Active | Solenoid Valve | 5/3 | - | -1 ~ 145 PSI (-0.1 ~ 10 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |
![]() |
CPE10-M1BH-3GL-QS-4SOLENOID VALVE |
3,648 |
|
![]() Tabla de datos |
CPE | Bulk | Active | Solenoid Valve | 3/2 Normally Closed | - | 36 ~ 116 PSI (2.5 ~ 8 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |
![]() |
CPE10-M1BH-3OL-QS-4SOLENOID VALVE |
2,939 |
|
![]() Tabla de datos |
CPE | Bulk | Active | Solenoid Valve | 3/2 Normally Open | - | 36 ~ 116 PSI (2.5 ~ 8 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |
![]() |
VYKB-F10-M32-16-PF-5HPAMEDIA SEPARATED SOLENOID VALVE |
4,754 |
|
![]() Tabla de datos |
VYKB | Bulk | Active | Solenoid Valve | 3/2 Normally Closed/Normally Open | - | - | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 12VDC |
![]() |
VYKB-F10-M32-16-PF-5HPSMEDIA SEPARATED SOLENOID VALVE |
3,949 |
|
![]() Tabla de datos |
VYKB | Bulk | Active | Solenoid Valve | 3/2 Normally Closed/Normally Open | - | - | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 12VDC |
![]() |
VSVA-B-M52-AZH-A1-1R5LSOLENOID VALVE |
3,486 |
|
![]() Tabla de datos |
VSVA | Bulk | Active | Solenoid Valve | 5/2 | - | -1 ~ 232 PSI (-0.1 ~ 16 bar) | - | Air | Threaded | Solenoid Valve | Sub-Base Mount | Supply Voltage 24VDC |
![]() |
VSVA-B-M52-AZH-A1-1R2LSOLENOID VALVE |
3,582 |
|
![]() Tabla de datos |
VSVA | Bulk | Active | Solenoid Valve | 5/2 | - | -1 ~ 232 PSI (-0.1 ~ 16 bar) | - | Air | Threaded | Solenoid Valve | Sub-Base Mount | Supply Voltage 24VDC |
![]() |
VSVA-B-M52-MZH-A1-1R5LSOLENOID VALVE |
2,453 |
|
![]() Tabla de datos |
VSVA | Bulk | Active | Solenoid Valve | 5/2 | - | -1 ~ 232 PSI (-0.1 ~ 16 bar) | - | Air | Threaded | Solenoid Valve | Sub-Base Mount | Supply Voltage 24VDC |
![]() |
VSVA-B-M52-MZH-A1-1R2LSOLENOID VALVE |
2,521 |
|
![]() Tabla de datos |
VSVA | Bulk | Active | Solenoid Valve | 5/2 | - | -1 ~ 232 PSI (-0.1 ~ 16 bar) | - | Air | Threaded | Solenoid Valve | Sub-Base Mount | Supply Voltage 24VDC |
![]() |
VSNC-FT-B52-G14-P2SOLENOID VALVE |
3,246 |
|
![]() Tabla de datos |
VSNC | Bulk | Active | Solenoid Valve | 5/2 | - | 22 ~ 116 PSI (1.5 ~ 8 bar) | - | Air | Threaded G1/4" | Solenoid Valve | Chassis Mount | - |
![]() |
VSNC-FT-B52-N14-P2SOLENOID VALVE |
3,667 |
|
![]() Tabla de datos |
VSNC | Bulk | Active | Solenoid Valve | 5/2 | - | 22 ~ 116 PSI (1.5 ~ 8 bar) | - | Air | Threaded 1/4" NPT | Solenoid Valve | Chassis Mount | - |
![]() |
CPE10-M1BH-5L-M5SOLENOID VALVE |
3,595 |
|
![]() Tabla de datos |
CPE | Bulk | Active | Solenoid Valve | 5/2 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air | Threaded M5 | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |
![]() |
CPE10-M1BH-5L-M7SOLENOID VALVE |
4,976 |
|
![]() Tabla de datos |
CPE | Bulk | Active | Solenoid Valve | 5/2 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air | Threaded M7 | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |
![]() |
CPE10-M1BH-3GL-QS-6SOLENOID VALVE |
3,093 |
|
![]() Tabla de datos |
CPE | Bulk | Active | Solenoid Valve | 3/2 Normally Closed | - | 36 ~ 116 PSI (2.5 ~ 8 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |
![]() |
CPE10-M1BH-3OL-QS-6SOLENOID VALVE |
4,540 |
|
![]() Tabla de datos |
CPE | Bulk | Active | Solenoid Valve | 3/2 Normally Open | - | 36 ~ 116 PSI (2.5 ~ 8 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |
![]() |
VN-20-L-T6-PQ4-VQ5-RO2VACUUM GENERATOR |
2,419 |
|
- |
VN | Bulk | Active | Vacuum Generator | - | - | 14.5 ~ 116 PSI (1 ~ 8 bar) | - | Air | Threaded | Control Valve | Chassis Mount | - |