Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo | Función | Tipo de actuador | Presión de funcionamiento | Diámetro del orificio | Tipo de fluido | Método de conexión | Para usar con/productos relacionados | Tipo de montaje | Características |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CPVSC1-M1H-N-P-M5OSOLENOID VALVE |
4,705 |
|
![]() Tabla de datos |
CPVSC | Bulk | Active | Solenoid Valve | 3/2 Normally Open | - | -13 ~ 102 PSI (-0.9 ~ 7 bar) | - | Air | Threaded M5 | Solenoid Valve | Chassis Mount | Supply Voltage 22VDC |
![]() |
CPVSC1-M1H-D-P-M5CSOLENOID VALVE |
4,965 |
|
![]() Tabla de datos |
CPVSC | Bulk | Active | Solenoid Valve | 2/2 Normally Closed | - | -13 ~ 102 PSI (-0.9 ~ 7 bar) | - | Air | Threaded M5 | Solenoid Valve | Chassis Mount | Supply Voltage 22VDC |
![]() |
CPVSC1-M1H-M-P-Q4SOLENOID VALVE |
2,705 |
|
![]() Tabla de datos |
CPVSC | Bulk | Active | Solenoid Valve | 5/2 | - | -13 ~ 102 PSI (-0.9 ~ 7 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 22VDC |
![]() |
CPVSC1-M1H-M-P-M5SOLENOID VALVE |
2,633 |
|
![]() Tabla de datos |
CPVSC | Bulk | Active | Solenoid Valve | 5/2 | - | -13 ~ 102 PSI (-0.9 ~ 7 bar) | - | Air | Threaded M5 | Solenoid Valve | Chassis Mount | Supply Voltage 22VDC |
![]() |
CPVSC1-M1H-D-P-Q3CSOLENOID VALVE |
3,050 |
|
![]() Tabla de datos |
CPVSC | Bulk | Active | Solenoid Valve | 2/2 Normally Closed | - | -13 ~ 102 PSI (-0.9 ~ 7 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 22VDC |
![]() |
CPVSC1-M1H-D-P-Q4CSOLENOID VALVE |
2,353 |
|
![]() Tabla de datos |
CPVSC | Bulk | Active | Solenoid Valve | 2/2 Normally Closed | - | -13 ~ 102 PSI (-0.9 ~ 7 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 22VDC |
![]() |
CPVSC1-M1H-K-P-Q4CSOLENOID VALVE |
3,616 |
|
![]() Tabla de datos |
CPVSC | Bulk | Active | Solenoid Valve | 3/2 Normally Closed | - | -13 ~ 102 PSI (-0.9 ~ 7 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 22VDC |
![]() |
CPE18-P1-3GLS-1/4BASIC VALVE |
3,020 |
|
![]() Tabla de datos |
CPE | Bulk | Active | Control Valve, Momentary | 3/2 Normally Closed | - | -13.05 ~ 145 PSI (-0.9 ~ 10 bar) | - | Air | Threaded G3/4" | Control Valve | Chassis Mount | - |
![]() |
CPE18-P1-3OLS-1/4BASIC VALVE |
2,250 |
|
![]() Tabla de datos |
CPE | Bulk | Active | Control Valve, Momentary | 3/2 Normally Open | - | -13.05 ~ 145 PSI (-0.9 ~ 10 bar) | - | Air | Threaded G3/4" | Control Valve | Chassis Mount | - |
![]() |
VSVA-B-M52-AH-A2-1C1SOLENOID VALVE |
3,191 |
|
![]() Tabla de datos |
VSVA | Bulk | Active | Solenoid Valve | 5/2 | - | 29 ~ 145 PSI (2 ~ 10 bar) | - | Air | Threaded G1/8" | Solenoid Valve | Sub-Base Mount | Supply Voltage 24VDC |
![]() |
VSVA-B-M52-MH-A2-1C1SOLENOID VALVE |
4,207 |
|
![]() Tabla de datos |
VSVA | Bulk | Active | Solenoid Valve | 5/2 | - | 44 ~ 145 PSI (3 ~ 10 bar) | - | Air | Threaded G1/8" | Solenoid Valve | Sub-Base Mount | Supply Voltage 24VDC |
![]() |
VHEF-VT-B32-G14TOGGLE LEVER VALVE |
3,459 |
|
- |
VHEF | Bulk | Active | Control Valve | 3/2 | - | -13.8 ~ 145PSI (-0.95 ~ 10 bar) | - | Air | Threaded G3/4" | Control Valve | Chassis Mount | - |
![]() |
VHEF-VT-M32-M-G14TOGGLE LEVER VALVE |
2,676 |
|
- |
VHEF | Bulk | Active | Control Valve | 3/2 Normally Closed/Normally Open | - | -13.8 ~ 145PSI (-0.95 ~ 10 bar) | - | Air | Threaded G3/4" | Control Valve | Chassis Mount | - |
![]() |
VHEF-VT-M32-M-N14TOGGLE LEVER VALVE |
4,004 |
|
- |
VHEF | Bulk | Active | Control Valve | 3/2 Normally Closed/Normally Open | - | -13.8 ~ 145PSI (-0.95 ~ 10 bar) | - | Air | Threaded 1/4" NPT | Control Valve | Chassis Mount | - |
![]() |
VHEF-VT-B32-N14TOGGLE LEVER VALVE |
3,992 |
|
- |
VHEF | Bulk | Active | Control Valve | 3/2 | - | -13.8 ~ 145PSI (-0.95 ~ 10 bar) | - | Air | Threaded 1/4" NPT | Control Valve | Chassis Mount | - |
![]() |
VSNC-FC-M52-MD-G14-FN-3AA1+GSOLENOID VALVE |
2,946 |
|
![]() Tabla de datos |
VSNC | Bulk | Active | Solenoid Valve | 3/2, 5/2 | - | 36 ~ 116 PSI (2.5 ~ 8 bar) | - | Air | Threaded G1/4" | Solenoid Valve | Chassis Mount | Supply Voltage 230VAC |
![]() |
VSNC-FC-M52-MD-G14-FN-1A1+GSOLENOID VALVE |
3,757 |
|
![]() Tabla de datos |
VSNC | Bulk | Active | Solenoid Valve | 3/2, 5/2 | - | 36 ~ 116 PSI (2.5 ~ 8 bar) | - | Air | Threaded G1/4" | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |
![]() |
VUVG-B18-P53C-ZT-F-1T1LSOLENOID VALVE |
4,946 |
|
![]() Tabla de datos |
VUVG | Bulk | Active | Solenoid Valve | 5/3 Normally Closed | - | -1 ~ 145 PSI (-0.1 ~ 10 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |
![]() |
VUVG-B18-P53E-ZT-F-1T1LSOLENOID VALVE |
2,456 |
|
![]() Tabla de datos |
VUVG | Bulk | Active | Solenoid Valve | 5/3 | - | -1 ~ 145 PSI (-0.1 ~ 10 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |
![]() |
VUVG-B18-P53U-ZT-F-1T1LSOLENOID VALVE |
4,445 |
|
![]() Tabla de datos |
VUVG | Bulk | Active | Solenoid Valve | 5/3 | - | -1 ~ 145 PSI (-0.1 ~ 10 bar) | - | Air | Threaded | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |