Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo | Rango de entrada | Salida | Aislamiento | Tiempo de respuesta | Precisión | Voltaje - Suministro | Tipo de montaje | Estilo de terminación | Temperatura de funcionamiento | Organismo de aprobación |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CR4560-50TRANSDUCER VOLTAGE 24VDC |
0 |
|
![]() Tabla de datos |
CR4500 | Bulk | Active | True RMS AC Voltage Transducer | 0 ~ 50VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
![]() |
CR6260-500-5TRANSDUCER AC 4-20MA OUT 3 PHASE |
0 |
|
![]() Tabla de datos |
CR6200 | Box | Active | Current Transducer | 0 ~ 500VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus, UL |
![]() |
ENTUBE DE-HB (1500V 10V SESC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±1500V | ±10V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (1000V 10V SESC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±1000V | ±10V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (750V 10V SESC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±750V | ±10V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (500V 10V SESC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±500V | ±10V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (300V 10V SESC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±300V | ±10V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (1500V10V SEBNC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±1500V | ±10V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | BNC, Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (750V10V SEBNC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±750V | ±10V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | BNC, Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (500V10V SEBNC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±500V | ±10V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | BNC, Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (300V10V SEBNC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±300V | ±10V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | BNC, Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (50V10V SEBNC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±50V | ±10V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | BNC, Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (1500V5V SEBNC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±1500V | ±5V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | BNC, Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (1000V5V SEBNC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±1000V | ±5V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | BNC, Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (750V5V SEBNC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±750V | ±5V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | BNC, Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (500V5V SEBNC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±500V | ±5V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | BNC, Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (300V5V SEBNC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±300V | ±5V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | BNC, Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (100V5V SEBNC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±100V | ±5V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | BNC, Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (1500V1V SEBNC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±1500V | ±1V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | BNC, Spring Terminal | -25°C ~ 70°C | - |
![]() |
ENTUBE DE-HB (1000V1V SEBNC)TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
![]() Tabla de datos |
Entube DE-HB | Box | Active | Voltage Transducer | ±1000V | ±1V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | BNC, Spring Terminal | -25°C ~ 70°C | - |