Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Programable | Tipo | Topología | Número de salidas | Voltaje: entrada (mín.) | Voltaje: entrada (máx.) | Voltaje - Salida | Corriente - Salida (máx.) | Potencia (vatios) | Voltaje - Aislamiento | Atenuación | Características | Clasificaciones | Temperatura de funcionamiento | Eficiencia | Estilo de terminación | Tamaño/Dimensión | Organismo de aprobación |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
ELP10-2060-UNV-1C10W, 20-60V, EMERGENCY DRIVER W/ |
8 |
|
![]() Tabla de datos |
- | Box | Active | - | Constant Power | AC DC Converter | 1 | 108V | 304.7VAC | 20 ~ 60V | 518mA | 10 W | - | - | Integrated Battery Backup, OCP, OVP, SCP | - | 0°C ~ 55°C | - | Wire Leads | 10.39" L x 1.69" W x 1.15" H (264.0mm x 42.9mm x 29.1mm) | cULus, FCC |
![]() |
XLG-320-H-APWR SUPP, BATT & COND |
12 |
|
![]() Tabla de datos |
XLG-320 (315W) | Bulk | Active | - | Constant Voltage | AC DC Converter | 1 | 100VAC | 305VAC | 48V | 6.5A | 312 W | 3.75 kV | PWM | OCP, OTP, OVP, SCP | IP67 | -20°C ~ 85°C | 93.5% | Wire Leads | 9.69" L x 3.03" W x 1.56" H (246.0mm x 77.0mm x 39.5mm) | CB, CCC, CE, EAC, ENEC, UKCA |
![]() |
USC4-200140GBLED DRIVER - 200W - CC |
19 |
|
![]() Tabla de datos |
USC4 LITE | Box | Active | - | Constant Current | AC DC Converter | 1 | 249VAC | 528VAC | 75 ~ 190V | 1.4A | 200 W | - | Analog | OCP, OTP, OVP, SCP | - | -40°C ~ 55°C | 93.5% | Wire Leads | 9.45" L x 2.36" W x 1.50" H (240.0mm x 59.9mm x 38.1mm) | cULus |
![]() |
HLG-120H-15BLED DRVR CC/CV AC/DC 7.5-15V 8A |
15 |
|
![]() Tabla de datos |
HLG-120H (120W) | Box | Active | Not Verified | Constant Current, Voltage | AC DC Converter | 1 | 90VAC | 305VAC | 7.5 ~ 15V | 8A | 120 W | 3.75 kV | Analog, PWM | OCP, OTP, OVP, SCP | IP67 | -40°C ~ 80°C | 92% | Wire Leads | 7.72" L x 2.68" W x 1.53" H (196.0mm x 68.0mm x 38.8mm) | CB, CCC, CE, cURus, ENEC, PSE, RCM, TUV |
![]() |
AB-D67320-V24-Q90-305VAC INPUT, 24VDC OUTPUT, 3 |
25 |
|
![]() Tabla de datos |
AB-D6x320-Vxx-Q | Box | Active | - | Constant Current, Voltage | AC DC Converter | 1 | 108VAC | 305VAC | 24V | 13.3A | 320 W | 3.2 kV | Non-Dimmable | OCP, OTP, OVP, SCP | IP67 | -40°C ~ 60°C | 93.5% | Wire Leads | 10.28" L x 1.95" W x 1.63" H (261.0mm x 49.5mm x 41.4mm) | CE, cULus, cURus, TUV, UKCA |
![]() |
HLG-150H-20BLED DRVR CC/CV AC/DC 10-20V 7.5A |
15 |
|
![]() Tabla de datos |
HLG-150H (150W) | Box | Active | Not Verified | Constant Current, Voltage | AC DC Converter | 1 | 90VAC | 305VAC | 10 ~ 20V | 7.5A | 150 W | 3.75 kV | Analog, PWM | OCP, OTP, OVP, SCP | IP67 | -40°C ~ 90°C | 93% | Wire Leads | 8.03" L x 2.68" W x 1.53" H (204.0mm x 68.0mm x 38.8mm) | CB, CCC, CE, cURus, PSE, RCM, TUV |
![]() |
XLG-320-L-APWR SUPP, BATT & COND |
10 |
|
![]() Tabla de datos |
XLG-320 (315W) | Bulk | Active | - | Constant Voltage | AC DC Converter | 1 | 100VAC | 305VAC | 48V | 6.5A | 312 W | 3.75 kV | PWM | OCP, OTP, OVP, SCP | IP67 | -20°C ~ 85°C | 93.5% | Wire Leads | 9.69" L x 3.03" W x 1.56" H (246.0mm x 77.0mm x 39.5mm) | CB, CCC, CE, EAC, ENEC, UKCA |
![]() |
XLG-320-M-APWR SUPP, BATT & COND |
12 |
|
![]() Tabla de datos |
XLG-320 (315W) | Bulk | Active | - | Constant Voltage | AC DC Converter | 1 | 100VAC | 305VAC | 48V | 6.5A | 312 W | 3.75 kV | PWM | OCP, OTP, OVP, SCP | IP67 | -20°C ~ 85°C | 93.5% | Wire Leads | 9.69" L x 3.03" W x 1.56" H (246.0mm x 77.0mm x 39.5mm) | CB, CCC, CE, EAC, ENEC, UKCA |
![]() |
HBG-240P-36BLED DVR CC/CV ACDC 21.6-36V 6.7A |
4 |
|
![]() Tabla de datos |
HBG-240P (240W) | Box | Active | Not Verified | Constant Current, Voltage | AC DC Converter | 1 | 90VAC | 305VAC | 21.6 ~ 36V | 6.7A | 241 W | 3.75 kV | Analog, PWM | OCP, OTP, OVP, SCP | - | - | 92.5% | Wire Leads | 5.67" Dia x 1.38" H (144.0mm x 35.0mm) | CB, CCC, CE, cURus, ENEC |
![]() |
HBG-240P-48BLED DRVR CC/CV AC/DC 28.8-48V 5A |
3 |
|
![]() Tabla de datos |
HBG-240P (240W) | Box | Active | Not Verified | Constant Current, Voltage | AC DC Converter | 1 | 90VAC | 305VAC | 28.8 ~ 48V | 5A | 240 W | 3.75 kV | Analog, PWM | OCP, OTP, OVP, SCP | - | - | 93% | Wire Leads | 5.67" Dia x 1.38" H (144.0mm x 35.0mm) | CB, CCC, CE, cURus, ENEC |
![]() |
ELG-240-48ABPWR SUPP, BATT & COND |
10 |
|
![]() Tabla de datos |
ELG-240 (240W) | Bulk | Active | - | Constant Current, Voltage | AC DC Converter | 1 | 100VAC | 305VAC | 48V | 5A | 240 W | 3.75 kV | Analog, PWM | OCP, OTP, OVP, SCP | IP65 | -40°C ~ 90°C (With Derating) | 93% | Wire Leads | 8.66" L x 2.80" W x 1.48" H (220.0mm x 71.0mm x 37.5mm) | CB, CCC, CE, EAC, ENEC, KC, RCM |
![]() |
HLG-120H-12ABO/P +12V10A |
15 |
|
![]() Tabla de datos |
HLG-120H (120W) | Box | Active | Not Verified | Constant Current, Voltage | AC DC Converter | 1 | 90VAC | 305VAC | 12V | 10A | 120 W | 3.75 kV | Analog, PWM | OCP, OTP, OVP, SCP | IP65 | -40°C ~ 80°C | 92% | Wire Leads | 7.72" L x 2.68" W x 1.53" H (196.0mm x 68.0mm x 38.8mm) | CB, CCC, CE, cURus, ENEC, KC, PSE, RCM, TUV |
![]() |
HLG-120H-48ABLED DRVR CC/CV AC/DC |
13 |
|
![]() Tabla de datos |
HLG-120H (120W) | Box | Active | Not Verified | Constant Current, Voltage | AC DC Converter | 1 | 90VAC | 305VAC | 48V | 2.5A | 120 W | 3.75 kV | - | OCP, OTP, OVP, SCP | IP65 | -40°C ~ 80°C | 93.5% | Wire Leads | 7.72" L x 2.68" W x 1.53" H (196.0mm x 68.0mm x 38.8mm) | CB, CCC, CE, cURus, ENEC, KC, PSE, RCM, TUV |
![]() |
HLG-150H-15ABO/P +15V10A |
15 |
|
![]() Tabla de datos |
HLG-150H (150W) | Box | Active | Not Verified | Constant Current, Voltage | AC DC Converter | 1 | 90VAC | 305VAC | 15V | 10A | 150 W | 3.75 kV | Analog, PWM | OCP, OTP, OVP, SCP | IP65 | -40°C ~ 90°C | 92% | Wire Leads | 8.03" L x 2.68" W x 1.53" H (204.0mm x 68.0mm x 38.8mm) | CB, CCC, CE, cURus, EAC, KC, PSE, RCM, TUV |
![]() |
HLG-150H-42ABO/P +42V3.6A |
12 |
|
![]() Tabla de datos |
HLG-150H (150W) | Box | Active | Not Verified | Constant Current, Voltage | AC DC Converter | 1 | 90VAC | 305VAC | 42V | 3.6A | 151 W | 3.75 kV | Analog, PWM | OCP, OTP, OVP, SCP | IP65 | -40°C ~ 90°C | 94% | Wire Leads | 8.03" L x 2.68" W x 1.53" H (204.0mm x 68.0mm x 38.8mm) | CB, CCC, CE, cURus, EAC, KC, PSE, RCM, TUV |
![]() |
HLG-150H-12ABLED DRVR CC/CV AC/DC |
12 |
|
![]() Tabla de datos |
HLG-150H (150W) | Box | Active | Not Verified | Constant Current, Voltage | AC DC Converter | 1 | 90VAC | 305VAC | 12V | 12.5A | 150 W | 3.75 kV | - | OCP, OTP, OVP, SCP | IP65 | -40°C ~ 90°C | 91.5% | Wire Leads | 8.03" L x 2.68" W x 1.53" H (204.0mm x 68.0mm x 38.8mm) | CB, CCC, CE, cURus, EAC, KC, PSE, RCM, TUV |
![]() |
HLG-150H-48ABLED DRVR CC/CV AC/DC |
12 |
|
![]() Tabla de datos |
HLG-150H (150W) | Box | Active | Not Verified | Constant Current, Voltage | AC DC Converter | 1 | 90VAC | 305VAC | 48V | 3.2A | 154 W | 3.75 kV | - | OCP, OTP, OVP, SCP | IP65 | -40°C ~ 90°C | 94% | Wire Leads | 8.03" L x 2.68" W x 1.53" H (204.0mm x 68.0mm x 38.8mm) | CB, CCC, CE, cURus, EAC, KC, PSE, RCM, TUV |
![]() |
HLG-150H-36ABLED DRVR CC/CV AC/DC |
8 |
|
![]() Tabla de datos |
HLG-150H (150W) | Box | Active | Not Verified | Constant Current, Voltage | AC DC Converter | 1 | 90VAC | 305VAC | 36V | 4.2A | 151 W | 3.75 kV | Analog, PWM | OCP, OTP, OVP, SCP | IP65 | -40°C ~ 90°C | 93.5% | Wire Leads | 8.03" L x 2.68" W x 1.53" H (204.0mm x 68.0mm x 38.8mm) | CB, CCC, CE, cURus, EAC, KC, PSE, RCM, TUV |
![]() |
ELG-240-48AB-3YLED AC/DC DRIVER 240W |
6 |
|
![]() Tabla de datos |
ELG-240 (240W) | Box | Active | Not Verified | Constant Current, Voltage | AC DC Converter | 1 | 100VAC | 305VAC | 48V | 5A | 240 W | 3.75 kV | - | OCP, OTP, OVP, SCP | IP65 | -40°C ~ 90°C | 93% | Wire Leads | 8.66" L x 2.80" W x 1.48" H (220.0mm x 71.0mm x 37.5mm) | CB, CCC, CE, cURus, EAC, ENEC, KC, RCM |
![]() |
HLN-80H-36ALED DRVR CC/CV AC/DC 36V 2.3A |
22 |
|
![]() Tabla de datos |
HLN-80H (80W) | Box | Not For New Designs | Not Verified | Constant Current, Voltage | AC DC Converter | 1 | 90VAC | 305VAC | 36V | 2.3A | 83 W | 3.75 kV | PWM | OCP, OTP, OVP, SCP | IP64 | -40°C ~ 50°C | 91% | Wire Leads | 6.34" L x 2.42" W x 1.38" H (161.0mm x 61.5mm x 35.0mm) | CB, CE, PSE, TUV |