Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Voltaje - Nominal | Tamaño/Dimensión | Ancho | Flujo de aire | Presión estática | Tipo de cojinete | Tipo de ventilador | Características | Ruido | Potencia (vatios) | RPM | Terminación | Protección de ingreso | Temperatura de funcionamiento | Organismo de aprobación | Peso |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
G9232M24B2-FSRFAN AXIAL 92X32MM 24VDC WIRE |
3,235 |
|
![]() Tabla de datos |
G9232 | Bulk | Active | 24VDC | Square - 92mm L x 92mm H | 32.00mm | 48.0 CFM (1.34m³/min) | 0.180 in H2O (44.8 Pa) | Ball | Tubeaxial | Locked Rotor Sensor, Thermal Overload Protector (TOP) | 32.0dB(A) | - | 2800 RPM | 3 Wire Leads | - | - | CE, cUL, TUV, UL | 0.335 lb (151.95 g) |
![]() |
G9232X12B1-FSRFAN AXIAL 92X32MM 12VDC WIRE |
4,450 |
|
![]() Tabla de datos |
G9232 | Bulk | Active | 12VDC | Square - 92mm L x 92mm H | 32.00mm | 68.0 CFM (1.90m³/min) | 0.330 in H2O (82.2 Pa) | Ball | Tubeaxial | Speed Sensor (Tach), Thermal Overload Protector (TOP) | 44.0dB(A) | - | 4000 RPM | 3 Wire Leads | - | - | CE, cUL, TUV, UL | 0.335 lb (151.95 g) |
![]() |
G9232X12B2-FSRFAN AXIAL 92X32MM 12VDC WIRE |
4,543 |
|
![]() Tabla de datos |
G9232 | Bulk | Active | 12VDC | Square - 92mm L x 92mm H | 32.00mm | 68.0 CFM (1.90m³/min) | 0.330 in H2O (82.2 Pa) | Ball | Tubeaxial | Locked Rotor Sensor, Thermal Overload Protector (TOP) | 44.0dB(A) | - | 4000 RPM | 3 Wire Leads | - | - | CE, cUL, TUV, UL | 0.335 lb (151.95 g) |
![]() |
G9232X24B1-FSRFAN AXIAL 92X32MM 24VDC WIRE |
4,367 |
|
![]() Tabla de datos |
G9232 | Bulk | Active | 24VDC | Square - 92mm L x 92mm H | 32.00mm | 68.0 CFM (1.90m³/min) | 0.330 in H2O (82.2 Pa) | Ball | Tubeaxial | Speed Sensor (Tach), Thermal Overload Protector (TOP) | 44.0dB(A) | - | 4000 RPM | 3 Wire Leads | - | - | CE, cUL, TUV, UL | 0.335 lb (151.95 g) |
![]() |
G9232H24B1-FSR-WSFAN AXIAL 92X32MM 24VDC WIRE |
3,205 |
|
![]() Tabla de datos |
G9232 | Bulk | Active | 24VDC | Square - 92mm L x 92mm H | 32.00mm | 55.0 CFM (1.54m³/min) | 0.240 in H2O (59.8 Pa) | Ball | Tubeaxial | Alarm Sensor, Speed Sensor (Tach), Thermal Overload Protector (TOP) | 35.0dB(A) | - | 3200 RPM | 4 Wire Leads | - | - | CE, cUL, TUV, UL | 0.335 lb (151.95 g) |
![]() |
CBM-7530BF-250-493-20DC BLOWER, 49.2 X 49.8 X 20 MM, |
3,926 |
|
![]() Tabla de datos |
CBM-75BF | Box | Active | 24VDC | Square/Rounded - 75.7mm L x 75.7mm H | 24.50mm | 14.7 CFM (0.412m³/min) | 0.850 in H2O (211.7 Pa) | Ball | Blower | Auto Restart, Speed Sensor (Tach) | 49.3dB(A) | 10.8 W | 5000 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, cURus, TUV | - |
![]() |
9GA0412G6001FAN AXIAL 40X20MM 12VDC WIRE |
2,014 |
|
![]() Tabla de datos |
San Ace 40 | Box | Active | 12VDC | Square - 40mm L x 40mm H | 20.00mm | 14.8 CFM (0.414m³/min) | 1.280 in H2O (318.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 47.0dB(A) | 2.76 W | 16000 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.078 lb (35.38 g) |
![]() |
OD4028-48LBThermal Products |
2,295 |
|
- |
OD4028 | Bulk | Active | 48VDC | Square - 40mm L x 40mm H | 28.00mm | 9.0 CFM (0.252m³/min) | 0.170 in H2O (42.3 Pa) | Ball | Tubeaxial | Auto Restart | 29.4dB(A) | 2.4 W | 6485 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, cURus, TUV, UR | - |
![]() |
OD4028-48MBThermal Products |
3,432 |
|
- |
OD4028 | Bulk | Active | 48VDC | Square - 40mm L x 40mm H | 28.00mm | 12.0 CFM (0.336m³/min) | 0.300 in H2O (74.7 Pa) | Ball | Tubeaxial | Auto Restart | 37.1dB(A) | 3.9 W | 8500 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, cURus, TUV, UR | - |
![]() |
OD4028-48HBThermal Products |
2,272 |
|
- |
OD4028 | Bulk | Active | 48VDC | Square - 40mm L x 40mm H | 28.00mm | 19.0 CFM (0.532m³/min) | 0.900 in H2O (224.2 Pa) | Ball | Tubeaxial | Auto Restart | 51.3dB(A) | 4.8 W | 10750 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, cURus, TUV, UR | - |
![]() |
9GA0412G7D001FAN AXIAL 40X15MM 12VDC WIRE |
2,069 |
|
![]() Tabla de datos |
San Ace 40 | Box | Active | 12VDC | Square - 40mm L x 40mm H | 15.00mm | 12.7 CFM (0.356m³/min) | 0.770 in H2O (191.8 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 42.0dB(A) | 2.04 W | 13100 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.062 lb (28.12 g) |
![]() |
9GA0412H7D001FAN AXIAL 40X15MM 12VDC WIRE |
4,528 |
|
![]() Tabla de datos |
San Ace 40 | Box | Active | 12VDC | Square - 40mm L x 40mm H | 15.00mm | 7.1 CFM (0.199m³/min) | 0.240 in H2O (59.8 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 28.0dB(A) | 720 mW | 7300 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.062 lb (28.12 g) |
![]() |
17000177AFAN 51.11X15MM CRB05112MB150300 |
2,429 |
|
![]() Tabla de datos |
- | Bulk | Obsolete | 12VDC | Rectangular/Rounded - 51.11mm L x 47.76mm H | 15.00mm | 3.3 CFM (0.092m³/min) | 0.350 in H2O (87.2 Pa) | Ball | Blower | Auto Restart, Locked Rotor Protection | 37.1dB(A) | 960 mW | 4500 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, cUL, TUV, UL | 0.057 lb (25.85 g) |
![]() |
17000179AFAN 51.11X15MM CRB05112LB150300 |
2,566 |
|
![]() Tabla de datos |
- | Bulk | Obsolete | 12VDC | Rectangular/Rounded - 51.11mm L x 47.76mm H | 15.00mm | 2.4 CFM (0.067m³/min) | 0.200 in H2O (49.8 Pa) | Ball | Blower | Auto Restart, Locked Rotor Protection | 31.6dB(A) | 600 mW | 3500 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, cUL, TUV, UL | 0.057 lb (25.85 g) |
![]() |
11925SA-24M-AA-00FAN AXIAL 119X25MM 24VDC WIRE |
3,543 |
|
![]() Tabla de datos |
11925SA | Box | Obsolete | 24VDC | Square - 119mm L x 119mm H | 25.00mm | 79.5 CFM (2.23m³/min) | 0.150 in H2O (37.3 Pa) | Ball | Tubeaxial | - | 33.5dB | 1.92 W | 2200 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | - | 0.309 lb (140.16 g) |
![]() |
11925SA-24N-EA-00FAN AXIAL 119X25MM 24VDC WIRE |
2,016 |
|
![]() Tabla de datos |
11925SA | Box | Obsolete | 24VDC | Square - 119mm L x 119mm H | 25.00mm | 91.0 CFM (2.55m³/min) | 0.190 in H2O (47.3 Pa) | Ball | Tubeaxial | - | 37.0dB | 2.64 W | 2500 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | - | 0.309 lb (140.16 g) |
![]() |
11925SA-24Q-EA-00FAN AXIAL 119X25MM 24VDC WIRE |
3,455 |
|
![]() Tabla de datos |
- | Bulk | Obsolete | 24VDC | Square - 119mm L x 119mm H | 25.00mm | 113.1 CFM (3.17m³/min) | 0.290 in H2O (72.2 Pa) | Ball | Tubeaxial | Auto Restart | 44.0dB | 4.8 W | 3100 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | - | - |
![]() |
PF60252B3-1000U-S9924VDC FAN 60X25MM TACH/PWM |
3,223 |
|
![]() Tabla de datos |
PF | Box | Active | 24VDC | Square - 60mm L x 60mm H | 25.00mm | 29.0 CFM (0.812m³/min) | 0.410 in H2O (102.1 Pa) | Ball | Tubeaxial | Auto Restart, PWM Control, Speed Sensor (Tach) | 37.5dB(A) | 1.56 W | 6200 RPM | 4 Wire Leads | - | - | CCC, CE, cURus, TUV, UKCA | - |
![]() |
PF60251B2-1000U-S9912VDC FAN 60X25MM TACH/PWM |
3,752 |
|
![]() Tabla de datos |
PF | Box | Active | 12VDC | Square - 60mm L x 60mm H | 25.00mm | 31.5 CFM (0.882m³/min) | 0.500 in H2O (124.5 Pa) | Ball | Tubeaxial | Auto Restart, PWM Control, Speed Sensor (Tach) | 40.7dB(A) | 1.98 W | 7000 RPM | 4 Wire Leads | - | - | CCC, CE, cURus, TUV, UKCA | - |
![]() |
PF60252B1-1000U-S9924VDC FAN 60X25MM TACH/PWM |
4,088 |
|
![]() Tabla de datos |
PF | Box | Active | 24VDC | Square - 60mm L x 60mm H | 25.00mm | 35.9 CFM (1.01m³/min) | 0.560 in H2O (139.5 Pa) | Ball | Tubeaxial | Auto Restart, PWM Control, Speed Sensor (Tach) | 41.7dB(A) | 2.57 W | 7500 RPM | 4 Wire Leads | - | - | CCC, CE, cURus, TUV, UKCA | - |