Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Voltaje - Nominal | Tamaño/Dimensión | Ancho | Flujo de aire | Presión estática | Tipo de cojinete | Tipo de ventilador | Características | Ruido | Potencia (vatios) | RPM | Terminación | Protección de ingreso | Temperatura de funcionamiento | Organismo de aprobación | Peso |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
R3G146-AK07-14EC BACKWARD-CURVED MOTORIZED IMP |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
W1G300-DC19-54DC AXIAL FAN |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
R3G250-AD62-30EC BACKWARD-CURVED MOTORIZED IMP |
0 |
|
- |
R3G250 | Bulk | Active | 48VDC | Round - 255mm Dia | 106.5mm | 930.0 CFM (26.04m³/min) | - | Ball | Motorized Impellers | PWM Control, Speed Sensor (Tach), Thermal Overload Protector (TOP) | - | 135 W | 2645 RPM | 4 Wire Leads | IP42 | -13 ~ 140°F (-25 ~ 60°C) | CCC, CSA, CE, EAC, UL | - |
![]() |
R3G280-AC66-30EC BACKWARD-CURVED MOTORIZED IMP |
0 |
|
- |
R3G280 | Bulk | Active | 48VDC | Round - 281mm Dia | 121.0mm | 748 CFM (20.94m³/min) | 0.542 in H2O (135.0 Pa) | Ball | Motorized Impellers | PWM Control, Speed Sensor (Tach), Thermal Overload Protector (TOP) | - | 135 W | 2000 RPM | 4 Wire Leads | IP42 | -13 ~ 140°F (-25 ~ 60°C) | CCC, CSA, CE, EAC, UL | - |
![]() |
K4D310-AB20-09MOTORIZED IMPELLER |
0 |
|
- |
K4D310 | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
W3G330-CA58-02EC AXIAL FAN |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
R3G310-BK02-01EC BACKWARD-CURVED MOTORIZED IMP |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
R1G310-AD19-52DC BACKWARD-CURVED MOTORIZED IMP |
0 |
|
- |
R1G310 | Bulk | Obsolete | 24VDC | Round - 318mm Dia | 120.0mm | - | - | Ball | Motorized Impellers | PWM Control, Speed Sensor (Tach) | - | 90 W | 1600 RPM | 4 Wire Leads | IP42 | -13 ~ 113°F (-25 ~ 45°C) | CSA, EAC, UL | - |
![]() |
D1G160-DA15-16DC CENTRIFUGAL BLOWER |
0 |
|
- |
D1G160 | Bulk | Active | 48VDC | Rectangular/Rounded - 260mm L x 227mm H | 214.0mm | 250.3 CFM (7.01m³/min) | 0.803 in H2O (200.0 Pa) | Ball | Blower, Centrifugal | PWM Control, Speed Sensor (Tach) | - | 165 W | 1750 RPM | 4 Wire Leads | IP42 | -13 ~ 140°F (-25 ~ 60°C) | - | - |
![]() |
G3G146-FN53-20DC CENTRIFUGAL BLOWER |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
R3G310-AL09-30FAN IMP MTRZD 318X150.0MM 48VDC |
0 |
|
![]() Tabla de datos |
R3G310 | Bulk | Obsolete | 48VDC | Round - 318mm Dia | 150.0mm | 913.0 CFM (25.56m³/min) | - | Ball | Motorized Impellers | PWM Control, Speed Sensor (Tach), Thermal Overload Protector (TOP) | 67.0dB(A) | 208 W | 1930 RPM | 4 Wire Leads with Ferrules | IP42 | -13 ~ 140°F (-25 ~ 60°C) | CCC, CE, CSA, EAC, UL | - |
![]() |
G1238E24B1+6-FSR-TTL-CC-3176FAN AXIAL 120X38MM 24VDC |
200 |
|
![]() Tabla de datos |
* | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
FBK04F24UFAN AXIAL 40X20MM 24VDC WIRE |
0 |
|
![]() Tabla de datos |
FBK | - | Obsolete | 24VDC | Square - 40mm L x 40mm H | 20.00mm | 9.2 CFM (0.258m³/min) | 0.472 in H2O (117.6 Pa) | Ball | Tubeaxial | - | 42.0dB(A) | 2.4 W | 9500 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | UL | 0.088 lb (39.92 g) |
![]() |
FBK04F05LFAN AXIAL 40X20MM BALL 5VDC WIRE |
0 |
|
![]() Tabla de datos |
FBK | - | Obsolete | 5VDC | Square - 40mm L x 40mm H | 20.00mm | 3.9 CFM (0.109m³/min) | 0.098 in H2O (24.5 Pa) | Ball | Tubeaxial | - | 24.0dB(A) | 600 mW | 4700 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | UL | 0.088 lb (39.92 g) |
![]() |
FBK04F05HFAN AXIAL 40X20MM BALL 5VDC WIRE |
0 |
|
![]() Tabla de datos |
FBK | - | Obsolete | 5VDC | Square - 40mm L x 40mm H | 20.00mm | 6.7 CFM (0.188m³/min) | 0.260 in H2O (64.8 Pa) | Ball | Tubeaxial | - | 33.0dB(A) | 1.4 W | 7500 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | UL | 0.088 lb (39.92 g) |
![]() |
FBK04F12LFAN AXIAL 40X20MM 12VDC WIRE |
0 |
|
![]() Tabla de datos |
FBK | - | Obsolete | 12VDC | Square - 40mm L x 40mm H | 20.00mm | 3.9 CFM (0.109m³/min) | 0.098 in H2O (24.5 Pa) | Ball | Tubeaxial | - | 23.0dB(A) | 900 mW | 4700 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | UL | 0.088 lb (39.92 g) |
![]() |
FBK04F12HFAN AXIAL 40X20MM 12VDC WIRE |
0 |
|
![]() Tabla de datos |
FBK | - | Obsolete | 12VDC | Square - 40mm L x 40mm H | 20.00mm | 6.7 CFM (0.188m³/min) | 0.260 in H2O (64.8 Pa) | Ball | Tubeaxial | - | 32.0dB(A) | 1.8 W | 7500 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | UL | 0.088 lb (39.92 g) |
![]() |
FAL5F12LLFAN BLOWER 76X28MM 12VDC WIRE |
0 |
|
![]() Tabla de datos |
FAL-5F | - | Obsolete | 12VDC | Square/Rounded - 76mm L x 76mm H | 28.00mm | 8.8 CFM (0.246m³/min) | 0.244 in H2O (60.8 Pa) | Hydro-wave (HWB) | Blower | - | 30.0dB | 1.68 W | 2400 RPM | 2 Wire Leads | - | 14 ~ 140°F (-10 ~ 60°C) | CSA, UL | 0.22 lb (99.79 g) |
![]() |
FAL6F12LLFAN BLOWER 109X28.1MM 12VDC WIRE |
0 |
|
![]() Tabla de datos |
FAL-6F | - | Obsolete | 12VDC | Rectangular/Rounded - 109mm L x 111.4mm H | 28.10mm | 18.7 CFM (0.524m³/min) | 0.443 in H2O (110.3 Pa) | Hydro-wave (HWB) | Blower | - | 40.0dB | 3.36 W | 2100 RPM | 2 Wire Leads | - | 14 ~ 140°F (-10 ~ 60°C) | CSA, UL | 0.551 lb (249.93 g) |
![]() |
FAL6F12LHFAN BLOWER 109X28.1MM 12VDC WIRE |
0 |
|
![]() Tabla de datos |
FAL-6F | - | Obsolete | 12VDC | Rectangular/Rounded - 109mm L x 111.4mm H | 28.10mm | 23.0 CFM (0.644m³/min) | 0.709 in H2O (176.6 Pa) | Hydro-wave (HWB) | Blower | - | 45.0dB | 6 W | 2550 RPM | 2 Wire Leads | - | 14 ~ 140°F (-10 ~ 60°C) | CSA, UL | 0.551 lb (249.93 g) |