Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Voltaje - Nominal | Tamaño/Dimensión | Ancho | Flujo de aire | Presión estática | Tipo de cojinete | Tipo de ventilador | Características | Ruido | Potencia (vatios) | RPM | Terminación | Protección de ingreso | Temperatura de funcionamiento | Organismo de aprobación | Peso |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
109E2024S0D01200X70MM 24V,RBLS DC LCKRTRSNS |
0 |
|
![]() Tabla de datos |
- | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
19040994AFAN MOTOR IMP 24VDC 225W 3350RPM |
0 |
|
![]() Tabla de datos |
Diplomat | Bulk | Active | 24VDC | Round - 227mm Dia | 99.00mm | 1005.0 CFM (28.14m³/min) | 3.580 in H2O (891.8 Pa) | Ball | Motorized Impellers | PWM Control, Speed Sensor (Tach) | - | 225 W | 3400 RPM | 4 Wire Leads | - | - | - | 3.5 lbs (1.6 kg) |
![]() |
19040997AFAN MOTOR IMP 48VDC 225W 3350RPM |
0 |
|
![]() Tabla de datos |
Diplomat | Bulk | Active | 48VDC | Round - 227mm Dia | 99.00mm | 1005.0 CFM (28.14m³/min) | 3.580 in H2O (891.8 Pa) | Ball | Motorized Impellers | PWM Control, Speed Sensor (Tach) | - | 225 W | 3400 RPM | 4 Wire Leads | - | - | - | 3.5 lbs (1.6 kg) |
![]() |
19040988AFAN MOTOR IMP 24VDC 233W 3369RPM |
0 |
|
![]() Tabla de datos |
Diplomat | Bulk | Active | 24VDC | Round - 227mm Dia | 99.00mm | 822.0 CFM (23.02m³/min) | 3.290 in H2O (820.0 Pa) | Ball | Motorized Impellers | Auto Restart, Locked Rotor Protection, Speed Sensor (Tach) | 79.4dB(A) | 190.5 W | 3350 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, cUL, UL | 3.5 lbs (1.6 kg) |
![]() |
19040991AFAN MOTOR IMP 48VDC 234W 3369RPM |
0 |
|
![]() Tabla de datos |
Diplomat | Bulk | Active | 48VDC | Round - 227mm Dia | 99.00mm | 822.0 CFM (23.02m³/min) | 3.290 in H2O (820.0 Pa) | Ball | Motorized Impellers | Auto Restart, Locked Rotor Protection, Speed Sensor (Tach) | 79.4dB(A) | 225.6 W | 3350 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, cUL, UL | 3.5 lbs (1.6 kg) |
![]() |
109E2048S0D01200X70MM 48V,RBLS DC LCKRTRSNS |
0 |
|
![]() Tabla de datos |
- | Box | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
9WL1448M1002DC AXIAL FAN 140X38 48V |
0 |
|
![]() Tabla de datos |
San Ace 140W | Box | Active | 48VDC | Square - 140mm L x 140mm H | 38.00mm | - | - | Ball | Tubeaxial | - | - | 7.2 W | - | 2 Wire Leads | - | - | - | - |
![]() |
9WL1448L1002140X38MM 48V,SPLASH & DUST PROOF |
0 |
|
![]() Tabla de datos |
San Ace 140W | Box | Active | 48VDC | Square - 140mm L x 140mm H | 38.00mm | - | - | Ball | Tubeaxial | Locked Rotor Protection | - | - | - | 2 Wire Leads | IP68 - Dust Tight, Waterproof | - | cURus, TUV | - |
![]() |
9WL1448M1001DC AXIAL FAN 140X38 48V TACH |
0 |
|
![]() Tabla de datos |
San Ace 140W | Box | Active | 48VDC | Square - 140mm L x 140mm H | 38.00mm | - | - | Ball | Tubeaxial | Speed Sensor (Tach) | - | 7.2 W | - | 3 Wire Leads | - | - | - | - |
![]() |
9WL1448L1001140X38MM 48V,SPLASH & DUST PROOF |
0 |
|
![]() Tabla de datos |
San Ace 140W | Box | Active | 48VDC | Square - 140mm L x 140mm H | 38.00mm | 91.9 CFM (2.60m³/min) | 0.320 in H2O (79.7 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 39.0dB(A) | 5.3 W | 2300 RPM | 3 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | - |
![]() |
9WL1448M1D001140X38MM 48V,SPLASH & DUST PROOF |
0 |
|
![]() Tabla de datos |
San Ace 140W | Box | Active | 48VDC | Square - 140mm L x 140mm H | 38.00mm | - | - | Ball | Tubeaxial | Locked Rotor Sensor | - | - | - | 3 Wire Leads | IP68 - Dust Tight, Waterproof | - | cURus, TUV | - |
![]() |
9WL1448L1D001140X38MM 48V,SPLASH & DUST PROOF |
0 |
|
![]() Tabla de datos |
San Ace 140W | Box | Active | 48VDC | Square - 140mm L x 140mm H | 38.00mm | - | - | Ball | Tubeaxial | Locked Rotor Sensor | - | - | - | 3 Wire Leads | IP68 - Dust Tight, Waterproof | - | cURus, TUV | - |
![]() |
W2G115-AG77-85FAN AXIAL 127X38MM BALL |
0 |
|
- |
W2G115 | Bulk | Obsolete | - | Square - 127mm L x 127mm H | 38.00mm | - | - | Ball | Tubeaxial | - | - | - | - | - | - | - | - | - |
![]() |
109E2024AS002200X70MM 24V,RBLS DC 0 |
0 |
|
![]() Tabla de datos |
San Ace 200 | Box | Active | 24VDC | Round - 200mm Dia | 70.00mm | 369.0 CFM (10.33m³/min) | 1.153 in H2O (287.1 Pa) | Ball | Tubeaxial | - | 57.0dB(A) | 45.6 W | 3200 RPM | 2 Wire Leads | - | 14 ~ 140°F (-10 ~ 60°C) | CSA, TUV, UR | - |
![]() |
109E2024MH002200X70MM 24V,RBLS DC 0 |
0 |
|
![]() Tabla de datos |
San Ace 200 | Box | Active | 24VDC | Round - 200mm Dia | 70.00mm | 289.5 CFM (8.11m³/min) | 0.771 in H2O (192.0 Pa) | Ball | Tubeaxial | - | 51.0dB(A) | 26.4 W | 2600 RPM | 2 Wire Leads | - | 14 ~ 140°F (-10 ~ 60°C) | CSA, TUV, UR | - |
![]() |
6314/2MPFAN AXIAL 171.5X50.8MM 24VDC |
0 |
|
![]() Tabla de datos |
6300, S-Force | Bulk | Active | 24VDC | Round - 171.5mm Dia | 50.80mm | 232.7 CFM (6.51m³/min) | - | Ball | Tubeaxial | Speed Sensor (Tach) | 51.0dB(A) | 14 W | 3700 RPM | 3 Wire Leads | IP54 - Dust Protected, Water Resistant | -4 ~ 167°F (-20 ~ 75°C) | - | - |
![]() |
REF100-11/14/2UFAN IMP MTRZD 104X24.9MM 24VDC |
0 |
|
- |
REF100 | Bulk | Active | 24VDC | Round - 104mm Dia | 24.90mm | 50.6 CFM (1.42m³/min) | - | Ball | Motorized Impellers | Speed Sensor (Tach) | - | 7.5 W | 5400 RPM | 3 Wire Leads | - | -4 ~ 167°F (-20 ~ 75°C) | - | - |
![]() |
109E5712K502FAN AXIAL 172X51MM 12VDC WIRE |
0 |
|
![]() Tabla de datos |
San Ace 172 | Box | Active | 12VDC | Rectangular/Rounded - 172mm L x 150mm H | 51.00mm | 300.0 CFM (8.40m³/min) | 0.976 in H2O (243.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 60.0dB(A) | 34.8 W | 4100 RPM | 2 Wire Leads | - | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | 1.7 lbs (760.0 g) |
![]() |
6314/2NPFAN AXIAL 171.5X50.8MM 24VDC |
0 |
|
![]() Tabla de datos |
6300, S-Force | Bulk | Active | 24VDC | Round - 171.5mm Dia | 50.80mm | 276.0 CFM (7.73m³/min) | - | Ball | Tubeaxial | Speed Sensor (Tach) | 56.0dB(A) | 23 W | 4400 RPM | 3 Wire Leads | IP54 - Dust Protected, Water Resistant | -4 ~ 158°F (-20 ~ 70°C) | - | - |
![]() |
RER101-36/14N/2HHA-184DC FLATPAK - RADIAL BLOWER |
0 |
|
- |
RER101 | Bulk | Active | 24VDC | Round - 101mm Dia | 51.90mm | 113.1 CFM (3.17m³/min) | 1.766 in H2O (440.0 Pa) | Ball | Motorized Impellers | Auto Restart, PWM Control, Speed Sensor (Tach) | - | 22.5 W | 6050 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CCC, CSA, CE, EAC, VDE, UL | - |