Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Voltaje - Nominal | Tamaño/Dimensión | Ancho | Flujo de aire | Presión estática | Tipo de cojinete | Tipo de ventilador | Características | Ruido | Potencia (vatios) | RPM | Terminación | Protección de ingreso | Temperatura de funcionamiento | Organismo de aprobación | Peso |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
55442.40890AC CROSSFLOW BLOWER |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
55442.45435AC CROSSFLOW BLOWER |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
UF175AMA23-H1C2AFAN IMP MTRZD 175X55MM 230VAC |
0 |
|
![]() Tabla de datos |
UF175AMA | Bulk | Active | 230VAC | Round - 175mm Dia | 55.00mm | 230.0 CFM (6.44m³/min) | 1.300 in H2O (323.6 Pa) | Ball | Motorized Impellers | Permanent Split Capacitor Motor, Thermal Overload Protector (TOP) | 70.0dB(A) | 66.0W | 2900 RPM | 4 Wire Leads | - | -40 ~ 158°F (-40 ~ 70°C) | CE, cUL, TUV, UL | 2.8 lbs (1.3 kg) |
![]() |
R2E190-AO50-16FAN IMP MTRZD 190X63MM 115VAC |
0 |
|
![]() Tabla de datos |
R2E190AO | Box | Not For New Designs | 115VAC | Round - 190mm Dia | 63.00mm | 365.0 CFM (10.22m³/min) | - | Ball | Motorized Impellers | - | 64.0dB(A) | 75.0W | 2700 RPM | 4 Wire Leads | - | - | - | 2.7 lbs (1.2 kg) |
![]() |
R87T-A6A15HPFAN AXIAL 120X38MM 230VAC TERM |
0 |
|
![]() Tabla de datos |
R87T | Bulk | Active | 230VAC | Square - 120mm L x 120mm H | 38.00mm | 107.1 CFM (3.00m³/min) | 0.236 in H2O (58.8 Pa) | Ball | Tubeaxial | - | 46.0dB | 18.00W | 3100 RPM | 2 Terminals | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, UL | 1.3 lbs (589.7 g) |
|
R87F-A1A13LPFAN AXIAL 120X25MM 100VAC TERM |
0 |
|
![]() Tabla de datos |
R87F | Bulk | Active | 100VAC | Square - 120mm L x 120mm H | 25.00mm | 53.5 CFM (1.50m³/min) | 0.079 in H2O (19.6 Pa) | Ball | Tubeaxial | - | 32.0dB | 12.00W | 1700 RPM | 2 Terminals | - | -22 ~ 158°F (-30 ~ 70°C) | CSA, UL | 0.772 lb (350.17 g) |
![]() |
OA180AN-22-3WB1856230VAC 176X176X89MM METAL |
0 |
|
![]() Tabla de datos |
OA180AN | Bulk | Active | 230VAC | Square - 176mm L x 176mm H | 89.00mm | 210.0 CFM (5.88m³/min) | 0.390 in H2O (97.1 Pa) | Ball | Tubeaxial | Capacitor, Thermal Overload Protector (TOP) | 41.0dB(A) | 30.00W | 1650 RPM | 2 Wire Leads | IP56 - Dust Protected, Water Resistant | -22 ~ 176°F (-30 ~ 80°C) | cURus, TUV | - |
![]() |
OA180AN-11-2TB1856115VAC 176X176X89MM METAL |
0 |
|
![]() Tabla de datos |
OA180AN | Bulk | Active | 115VAC | Square - 176mm L x 176mm H | 89.00mm | 275.0 CFM (7.70m³/min) | 0.530 in H2O (132.0 Pa) | Ball | Tubeaxial | Capacitor, Thermal Overload Protector (TOP) | 52.0dB(A) | 65.0W | 2250 RPM | 2 Terminals | IP56 - Dust Protected, Water Resistant | -22 ~ 176°F (-30 ~ 80°C) | cURus, TUV | - |
![]() |
OA180AN-22-2TB1856230VAC 176X176X89MM METAL |
0 |
|
![]() Tabla de datos |
OA180AN | Bulk | Active | 230VAC | Square - 176mm L x 176mm H | 89.00mm | 275.0 CFM (7.70m³/min) | 0.530 in H2O (132.0 Pa) | Ball | Tubeaxial | Capacitor, Thermal Overload Protector (TOP) | 52.0dB(A) | 65.0W | 2250 RPM | 2 Terminals | IP56 - Dust Protected, Water Resistant | -22 ~ 176°F (-30 ~ 80°C) | cURus, TUV | - |
![]() |
OA180AN-22-3TB1856230VAC 176X176X89MM METAL |
0 |
|
![]() Tabla de datos |
OA180AN | Bulk | Active | 230VAC | Square - 176mm L x 176mm H | 89.00mm | 210.0 CFM (5.88m³/min) | 0.390 in H2O (97.1 Pa) | Ball | Tubeaxial | Capacitor, Thermal Overload Protector (TOP) | 41.0dB(A) | 30.00W | 1650 RPM | 2 Terminals | IP56 - Dust Protected, Water Resistant | -22 ~ 176°F (-30 ~ 80°C) | cURus, TUV | - |
![]() |
OA180AN-11-3WB1856115VAC 176X176X89MM METAL |
0 |
|
![]() Tabla de datos |
OA180AN | Bulk | Active | 115VAC | Square - 176mm L x 176mm H | 89.00mm | 210.0 CFM (5.88m³/min) | 0.390 in H2O (97.1 Pa) | Ball | Tubeaxial | Capacitor, Thermal Overload Protector (TOP) | 41.0dB(A) | 30.00W | 1650 RPM | 2 Wire Leads | IP56 - Dust Protected, Water Resistant | -22 ~ 176°F (-30 ~ 80°C) | cURus, TUV | - |
![]() |
OA180AN-11-2WB1856115VAC 176X176X89MM METAL |
0 |
|
![]() Tabla de datos |
OA180AN | Bulk | Active | 115VAC | Square - 176mm L x 176mm H | 89.00mm | 275.0 CFM (7.70m³/min) | 0.530 in H2O (132.0 Pa) | Ball | Tubeaxial | Capacitor, Thermal Overload Protector (TOP) | 52.0dB(A) | 65.0W | 2250 RPM | 2 Wire Leads | IP56 - Dust Protected, Water Resistant | -22 ~ 176°F (-30 ~ 80°C) | cURus, TUV | - |
![]() |
OA180AN-22-2WB1856230VAC 176X176X89MM METAL |
0 |
|
![]() Tabla de datos |
OA180AN | Bulk | Active | 230VAC | Square - 176mm L x 176mm H | 89.00mm | 275.0 CFM (7.70m³/min) | 0.530 in H2O (132.0 Pa) | Ball | Tubeaxial | Capacitor, Thermal Overload Protector (TOP) | 52.0dB(A) | 65.0W | 2250 RPM | 2 Wire Leads | IP56 - Dust Protected, Water Resistant | -22 ~ 176°F (-30 ~ 80°C) | cURus, TUV | - |
![]() |
OA180AN-11-3TB1856115VAC 176X176X89MM METAL |
0 |
|
![]() Tabla de datos |
OA180AN | Bulk | Active | 115VAC | Square - 176mm L x 176mm H | 89.00mm | 210.0 CFM (5.88m³/min) | 0.390 in H2O (97.1 Pa) | Ball | Tubeaxial | Capacitor, Thermal Overload Protector (TOP) | 41.0dB(A) | 30.00W | 1650 RPM | 2 Terminals | IP56 - Dust Protected, Water Resistant | -22 ~ 176°F (-30 ~ 80°C) | cURus, TUV | - |
![]() |
55410.91580FAN BLOWER CROSSFLOW |
0 |
|
- |
QLZ06AC | Bulk | Active | 115VAC | Rectangular - 257mm L x 61mm H (60mm Dia) | 83.00mm | 114.0 CFM (3.19m³/min) | 0.401 in H2O (100.0 Pa) | Sleeve | Blower, Cross Flow | - | - | 43.00W | 2200 RPM | - | - | 32 ~ 140°F (0 ~ 60°C) | - | - |
![]() |
55330.0121MOTOR,AXIAL,115VAC,-CFM,15W-A,15 |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
AC4300/19H-012FAN AXIAL 119X32MM 85/265VAC |
0 |
|
- |
ACmaxx, AC4300 | Bulk | Active | 115VAC | Square - 119mm L x 119mm H | 32.00mm | 120.2 CFM (3.37m³/min) | - | Ball | Tubeaxial | Alarm, Electronic Commutation (EC), Locked Rotor Protection | 51.0dB(A) | 12.00W | 3400 RPM | 3 Wire Leads | IP21 | -4 ~ 158°F (-20 ~ 70°C) | - | - |
![]() |
109S493-20FAN 92X25MM 115VAC ALARM |
0 |
|
![]() Tabla de datos |
San Ace 92 | Box | Active | 115VAC | Square - 92mm L x 92mm H | 25.00mm | 38.9 CFM (1.09m³/min) | 0.197 in H2O (49.0 Pa) | Ball | Tubeaxial | Alarm | 38.0dB(A) | 7.00W | 3100 RPM | 3 Wire Leads | - | 14 ~ 140°F (-10 ~ 60°C) | CE, PSE, TUV, UL | 0.683 lb (309.8 g) |
![]() |
109S493-30FAN 92X25MM 115VAC ALARM |
0 |
|
![]() Tabla de datos |
San Ace 92 | Box | Active | 115VAC | Square - 92mm L x 92mm H | 25.00mm | 38.9 CFM (1.09m³/min) | 0.197 in H2O (49.0 Pa) | Ball | Tubeaxial | Alarm | 38.0dB(A) | 7.00W | 3100 RPM | 3 Wire Leads | - | 14 ~ 140°F (-10 ~ 60°C) | CE, PSE, TUV, UL | 0.683 lb (309.8 g) |
![]() |
109S491-3092X25MM 100V,MINI ACE, SNSR VLT |
0 |
|
![]() Tabla de datos |
San Ace 92 | Box | Active | 100VAC | Square - 92mm L x 92mm H | 25.00mm | 38.9 CFM (1.09m³/min) | 0.197 in H2O (49.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 38.0dB(A) | 7.00W | 3100 RPM | 3 Wire Leads | - | 14 ~ 140°F (-10 ~ 60°C) | CE, CSA, PSE, TUV, UR | - |