| Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Estilo de conector | Tipo de conector | Número de posiciones | Número de filas | Tipo de montaje | Tamaño de la carcasa, disposición del conector | Tipo de contacto | Característica de la brida | Terminación | Material principal | Material de la carcasa, acabado | Acabado de contacto | Grosor del acabado del contacto | Protección de ingreso | Índice de inflamabilidad del material | Clasificación de corriente (amperios) | Espaciado de retroceso | Características |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
634-044-263-051CONN D-SUB HD RCPT 44P R/A SLDR |
3,819 |
|
Tabla de datos |
634 | Tray | Active | D-Sub, High Density | Receptacle, Female Sockets | 44 | 3 | Board Edge, Through Hole, Right Angle | 3 (DB, B) High Density | Signal | Housing/Shell (Unthreaded) | Solder | - | Steel, Nickel Plated | Gold | Flash | - | UL94 V-0 | 3A per Contact | 0.350" (8.89mm) | Mounting Brackets, Shielded |
|
638-015-331-052CONN D-SUB HD RCPT 15P VERT SLDR |
4,607 |
|
Tabla de datos |
638 | Tray | Active | D-Sub, High Density | Receptacle, Female Sockets | 15 | 3 | Through Hole | 1 (DE, E) High Density | Signal | Housing/Shell (4-40) | Solder | - | Steel, Nickel Plated | Gold | 15.0µin (0.38µm) | - | UL94 V-0 | 3A per Contact | - | Shielded |
|
634-044-263-035CONN D-SUB HD RCPT 44P R/A SLDR |
3,577 |
|
Tabla de datos |
634 | Tray | Active | D-Sub, High Density | Receptacle, Female Sockets | 44 | 3 | Board Edge, Through Hole, Right Angle | 3 (DB, B) High Density | Signal | Housing/Shell (M3) | Solder | - | Steel, Nickel Plated | Gold | Flash | - | UL94 V-0 | 3A per Contact | 0.350" (8.89mm) | Board Lock, Mounting Brackets, Shielded |
|
633-015-363-053CONN D-SUB HD PLG 15POS R/A SLDR |
2,066 |
|
Tabla de datos |
633 | Tray | Active | D-Sub, High Density | Plug, Male Pins | 15 | 3 | Board Edge, Through Hole, Right Angle | 1 (DE, E) High Density | Signal | Mating Side, Female Screwlock (4-40) | Solder | - | Steel, Nickel Plated | Gold | 15.0µin (0.38µm) | - | UL94 V-0 | 3A per Contact | 0.350" (8.89mm) | Board Lock, Grounding Indents, Mounting Brackets, Shielded |
|
633-015-363-040CONN D-SUB HD PLG 15POS R/A SLDR |
3,600 |
|
Tabla de datos |
633 | Tray | Active | D-Sub, High Density | Plug, Male Pins | 15 | 3 | Board Edge, Through Hole, Right Angle | 1 (DE, E) High Density | Signal | Mating Side (4-40) | Solder | - | Steel, Nickel Plated | Gold | 15.0µin (0.38µm) | - | UL94 V-0 | 3A per Contact | 0.350" (8.89mm) | Board Lock, Grounding Indents, Mounting Brackets, Shielded |
|
637-044-232-048CONN D-SUB HD PLG 44POS SLDR CUP |
3,802 |
|
Tabla de datos |
637 | Tray | Active | D-Sub, High Density | Plug, Male Pins | 44 | 3 | Free Hanging (In-Line) | 3 (DB, B) High Density | Signal | Mating Side (4-40) | Solder Cup | - | Steel, Nickel Plated | Gold | Flash | - | UL94 V-0 | 3A per Contact | - | Grounding Indents, Shielded |
|
633-015-663-052CONN D-SUB HD PLG 15POS R/A SLDR |
3,207 |
|
Tabla de datos |
633 | Tray | Active | D-Sub, High Density | Plug, Male Pins | 15 | 3 | Board Edge, Through Hole, Right Angle | 1 (DE, E) High Density | Signal | Housing/Shell (4-40) | Solder | - | Steel, Nickel Plated | Gold | 30.0µin (0.76µm) | - | UL94 V-0 | 3A per Contact | 0.350" (8.89mm) | Board Lock, Grounding Indents, Mounting Brackets, Shielded |
|
629-037-240-043CONN D-SUB PLUG 37POS R/A SOLDER |
2,630 |
|
Tabla de datos |
629 | Tray | Active | D-Sub | Plug, Male Pins | 37 | 2 | Panel Mount, Through Hole, Right Angle | 4 (DC, C) | Signal | Mating Side, Female Screwlock (4-40) | Solder | - | Steel, Nickel Plated | Gold | Flash | - | UL94 V-0 | 3A per Contact | 0.409" (10.40mm) | Board Lock, Grounding Indents, Mounting Brackets, Shielded |
|
629-037-240-013CONN D-SUB PLUG 37POS R/A SOLDER |
4,529 |
|
Tabla de datos |
629 | Tray | Active | D-Sub | Plug, Male Pins | 37 | 2 | Panel Mount, Through Hole, Right Angle | 4 (DC, C) | Signal | Mating Side, Female Screwlock (4-40) | Solder | - | Steel, Nickel Plated | Gold | Flash | - | UL94 V-0 | 3A per Contact | 0.409" (10.40mm) | Grounding Indents, Mounting Brackets, Shielded |
|
633-015-663-055CONN D-SUB HD PLG 15POS R/A SLDR |
3,756 |
|
Tabla de datos |
633 | Tray | Active | D-Sub, High Density | Plug, Male Pins | 15 | 3 | Board Edge, Through Hole, Right Angle | 1 (DE, E) High Density | Signal | Housing/Shell (M3) | Solder | - | Steel, Nickel Plated | Gold | 30.0µin (0.76µm) | - | UL94 V-0 | 3A per Contact | 0.350" (8.89mm) | Board Lock, Grounding Indents, Mounting Brackets, Shielded |
|
633-015-363-043CONN D-SUB HD PLG 15POS R/A SLDR |
3,192 |
|
Tabla de datos |
633 | Tray | Active | D-Sub, High Density | Plug, Male Pins | 15 | 3 | Board Edge, Through Hole, Right Angle | 1 (DE, E) High Density | Signal | Mating Side, Female Screwlock (4-40) | Solder | - | Steel, Nickel Plated | Gold | 15.0µin (0.38µm) | - | UL94 V-0 | 3A per Contact | 0.350" (8.89mm) | Board Lock, Grounding Indents, Mounting Brackets, Shielded |
|
633-015-663-031CONN D-SUB HD PLG 15POS R/A SLDR |
2,692 |
|
Tabla de datos |
633 | Tray | Active | D-Sub, High Density | Plug, Male Pins | 15 | 3 | Board Edge, Through Hole, Right Angle | 1 (DE, E) High Density | Signal | Housing/Shell (Unthreaded) | Solder | - | Steel, Nickel Plated | Gold | 30.0µin (0.76µm) | - | UL94 V-0 | 3A per Contact | 0.350" (8.89mm) | Board Lock, Grounding Indents, Mounting Brackets, Shielded |
|
633-015-663-015CONN D-SUB HD PLG 15POS R/A SLDR |
4,885 |
|
Tabla de datos |
633 | Tray | Active | D-Sub, High Density | Plug, Male Pins | 15 | 3 | Board Edge, Through Hole, Right Angle | 1 (DE, E) High Density | Signal | Housing/Shell (M3) | Solder | - | Steel, Nickel Plated | Gold | 30.0µin (0.76µm) | - | UL94 V-0 | 3A per Contact | 0.350" (8.89mm) | Grounding Indents, Mounting Brackets, Shielded |
|
630-037-240-013CONN D-SUB RCPT 37POS R/A SOLDER |
2,347 |
|
Tabla de datos |
630 | Tray | Active | D-Sub | Receptacle, Female Sockets | 37 | 2 | Board Edge, Through Hole, Right Angle | 4 (DC, C) | Signal | Mating Side, Female Screwlock (4-40) | Solder | - | Steel, Nickel Plated | Gold | Flash | - | UL94 V-0 | 3A per Contact | 0.409" (10.40mm) | Board Lock, Mounting Brackets, Shielded |
|
633-015-663-051CONN D-SUB HD PLG 15POS R/A SLDR |
4,083 |
|
Tabla de datos |
633 | Tray | Active | D-Sub, High Density | Plug, Male Pins | 15 | 3 | Board Edge, Through Hole, Right Angle | 1 (DE, E) High Density | Signal | Housing/Shell (Unthreaded) | Solder | - | Steel, Nickel Plated | Gold | 30.0µin (0.76µm) | - | UL94 V-0 | 3A per Contact | 0.350" (8.89mm) | Board Lock, Grounding Indents, Mounting Brackets, Shielded |
|
633-015-363-030CONN D-SUB HD PLG 15POS R/A SLDR |
2,370 |
|
Tabla de datos |
633 | Tray | Active | D-Sub, High Density | Plug, Male Pins | 15 | 3 | Board Edge, Through Hole, Right Angle | 1 (DE, E) High Density | Signal | Mating Side (4-40) | Solder | - | Steel, Nickel Plated | Gold | 15.0µin (0.38µm) | - | UL94 V-0 | 3A per Contact | 0.350" (8.89mm) | Board Lock, Grounding Indents, Mounting Brackets, Shielded |
|
637-044-232-049CONN D-SUB HD PLG 44POS SLDR CUP |
3,603 |
|
Tabla de datos |
637 | Tray | Active | D-Sub, High Density | Plug, Male Pins | 44 | 3 | Free Hanging (In-Line) | 3 (DB, B) High Density | Signal | Board Side (4-40) | Solder Cup | - | Steel, Nickel Plated | Gold | Flash | - | UL94 V-0 | 3A per Contact | - | Grounding Indents, Shielded |
|
638-026-232-267CONN D-SUB HD RCPT 26P SLDR CUP |
2,905 |
|
Tabla de datos |
638 | Tray | Active | D-Sub, High Density | Receptacle, Female Sockets | 26 | 3 | Free Hanging (In-Line) | 2 (DA, A) High Density | Signal | Mating Side, Female Screwlock (4-40) | Solder Cup | - | Steel, Tin Plated | Gold | Flash | - | UL94 V-0 | 3A per Contact | - | Board Lock, Shielded |
|
637-044-230-241CONN D-SUB HD PLUG 44POS PNL MNT |
4,718 |
|
Tabla de datos |
637 | Tray | Active | D-Sub, High Density | Plug, Male Pins | 44 | 3 | Panel Mount, Through Hole | 3 (DB, B) High Density | Signal | Housing/Shell (Unthreaded) | Solder | - | Steel, Tin Plated | Gold | Flash | - | UL94 V-0 | 3A per Contact | - | Grounding Indents, Shielded |
|
637-015-632-068CONN D-SUB HD PLG 15POS SLDR CUP |
3,872 |
|
Tabla de datos |
637 | Tray | Active | D-Sub, High Density | Plug, Male Pins | 15 | 3 | Free Hanging (In-Line) | 1 (DE, E) High Density | Signal | Mating Side (4-40) | Solder Cup | - | Steel, Nickel Plated | Gold | 30.0µin (0.76µm) | - | UL94 V-0 | 3A per Contact | - | Grounding Indents, Shielded |