Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo | Número de salidas | Voltaje - Entrada | Voltaje - Salida 1 | Voltaje - Salida 2 | Voltaje - Salida 3 | Voltaje - Salida 4 | Voltaje - Salida 5 | Voltaje - Salida 6 | Corriente - Salida 1 | Corriente - Salida 2 | Corriente - Salida 3 | Corriente - Salida 4 | Corriente - Salida 5 | Corriente - Salida 6 | Potencia (vatios) | Aplicaciones | Voltaje - Aislamiento | Temperatura de funcionamiento | Características | Tipo de montaje | Tamaño/Dimensión |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CX10S-BBBBBC-P-A-DK00000AC/DC CONVERTER 24V 5X12V 1000W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 6 | 85 ~ 264 VAC | 12V | 12V | 12V | 12V | 12V | 24V | 15 A | 15 A | 15 A | 15 A | 15 A | 8.3 A | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-BBBBGB-P-A-DK00000AC/DC CNVT 12V 2X24V 3X12V 1000W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 7 | 85 ~ 264 VAC | 12V | 12V | 12V | 12V | 24V | 24V | 15 A | 15 A | 15 A | 15 A | 3 A | 3 A | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-CG0CHD-P-A-DK00000AC/DC CNVT 48V 5V 4X24V 820W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 7 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 5V | 24V | 8.3 A | 3 A | 3 A | 8.3 A | 6 A | 3 A | 820W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-BGGGGG-P-A-DK00000AC/DC CONVERTER 6X24V 24V 780W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 11 | 85 ~ 264 VAC | 12V | 24V | 24V | 24V | 24V | 24V | 15 A | 3 A | 3 A | 3 A | 3 A | 3 A | 780W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-CGCCCC-P-A-DK00000AC/DC CONVERTER 6X24V 24V 1000W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 7 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 24V | 24V | 8.3 A | 3 A | 3 A | 8.3 A | 8.3 A | 8.3 A | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-BHHBBB-P-A-DK00000AC/DC CNVT 3X12V 2X5V 2X24V 920W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 5V | 24V | 5V | 24V | 12V | 15 A | 6 A | 3 A | 6 A | 3 A | 15 A | 920W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-CDDGAG-P-A-DK00000AC/DC CNVT 2X24V 5V 24V 48V 24V |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 48V | 48V | 24V | 24V | 5V | 8.3 A | 4.17 A | 4.17 A | 3 A | 3 A | 21 A | 945W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-CCGHGG-P-A-DK00000AC/DC CONVERTER 5X24V 5V 860W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 10 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 5V | 24V | 8.3 A | 8.3 A | 3 A | 3 A | 6 A | 3 A | 860W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-CGDGHB-P-A-DK00000AC/DC CNVT 12V 5V 5X24V 920W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 9 | 85 ~ 264 VAC | 24V | 24V | 24V | 48V | 24V | 24V | 8.3 A | 3 A | 3 A | 4.17 A | 3 A | 3 A | 920W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-BH0G00-P-A-DK00000AC/DC CNVT 12V 5V 3X24V 400W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 5 | 85 ~ 264 VAC | 12V | 5V | 24V | 24V | 24V | - | 15 A | 6 A | 3 A | 3 A | 3 A | - | 400W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-BHBBBB-P-A-DK00000AC/DC CNVT 4X12V 5V 24V 5V 1000W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 7 | 85 ~ 264 VAC | 12V | 5V | 24V | 12V | 12V | 12V | 15 A | 6 A | 3 A | 15 A | 15 A | 15 A | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-CCCBBB-P-A-DK00000AC/DC CNVT 3X12V 3X24V 1000W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 6 | 85 ~ 264 VAC | 24V | 24V | 24V | 12V | 12V | 12V | 8.3 A | 8.3 A | 8.3 A | 15 A | 15 A | 15 A | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-CCCBBC-P-A-DK00000AC/DC CNVT 24V 2X12V 3X24V 1000W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 6 | 85 ~ 264 VAC | 24V | 24V | 24V | 12V | 12V | 24V | 8.3 A | 8.3 A | 8.3 A | 15 A | 15 A | 8.3 A | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-CBDCDC-P-A-DK00000AC/DC CNVT 24V 48V 24V 48V 2X12V |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 6 | 85 ~ 264 VAC | 24V | 12V | 48V | 24V | 48V | 24V | 8.3 A | 15 A | 4.17 A | 8.3 A | 4.17 A | 8.3 A | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-B00000-P-A-DK00000AC/DC CONVERTER 12V 180W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 15 A | - | - | - | - | - | 180W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-BHGGHH-P-A-DK00000ACDC CNVT 5V 24V 5V 24V 5V 2X24V |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 11 | 85 ~ 264 VAC | 12V | 5V | 24V | 24V | 24V | 24V | 15 A | 6 A | 3 A | 3 A | 3 A | 3 A | 720W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-B0DBDD-P-A-DK00000ACDC CNVT 12V 48V 12V 2X48V 960W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 5 | 85 ~ 264 VAC | 12V | 48V | 12V | 48V | 48V | - | 15 A | 4.17 A | 15 A | 4.17 A | 4.17 A | - | 960W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-0AH0CH-P-A-DK00000AC/DC CNVT 5V 2X24V 5V 24V 505W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 6 | 85 ~ 264 VAC | 5V | 5V | 24V | 24V | 5V | 24V | 21 A | 6 A | 3 A | 8.3 A | 6 A | 3 A | 505W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-BHBHBH-P-A-DK00000AC/DC CNVT 5V 24V 12V 2X5V 2X24V |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 9 | 85 ~ 264 VAC | 12V | 5V | 24V | 12V | 5V | 24V | 15 A | 6 A | 3 A | 15 A | 6 A | 3 A | 840W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-BBHBBB-P-A-DK00000ACDC CNVT 3X12V 5V 12V 24V 1000W |
0 |
|
![]() Tabla de datos |
COOLX®1000 | Box | Active | Enclosed | 7 | 85 ~ 264 VAC | 12V | 12V | 5V | 24V | 12V | 12V | 15 A | 15 A | 6 A | 3 A | 15 A | 15 A | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |