Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo | Número de salidas | Voltaje - Entrada | Voltaje - Salida 1 | Voltaje - Salida 2 | Voltaje - Salida 3 | Voltaje - Salida 4 | Voltaje - Salida 5 | Voltaje - Salida 6 | Corriente - Salida 1 | Corriente - Salida 2 | Corriente - Salida 3 | Corriente - Salida 4 | Corriente - Salida 5 | Corriente - Salida 6 | Potencia (vatios) | Aplicaciones | Voltaje - Aislamiento | Temperatura de funcionamiento | Características | Tipo de montaje | Tamaño/Dimensión |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
MP6-1D-1E-1R-4EE-4NN-00AC/DC CNVT 3.3V 5V 28V 3X5V 800W |
4,012 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 7 | 85 ~ 264 VAC, 120 ~ 300 VDC | 3.3V | 5V | 28V | 5V | 5V | 15V | 35 A | 35 A | 6.7 A | 10 A | 10 A | 8 A | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-2N-1N-LLE-01AC/DC CNVT 2X15V 2X12V 5V 800W |
3,567 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 5 | 85 ~ 264 VAC, 120 ~ 300 VDC | 15V | 15V | 12V | 12V | 5V | - | 20 A | 14 A | 1 A | 1 A | 2 A | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | 11.00" L x 5.00" W x 2.50" H (279.4mm x 127.0mm x 63.5mm) |
|
MP6-1L-1Y-1Y-00AC/DC CONVERTER 12V 2X60V 800W |
3,800 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 3 | 85 ~ 264 VAC, 120 ~ 300 VDC | 12V | 60V | 60V | - | - | - | 17 A | 3.5 A | 3.5 A | - | - | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-2Y-1L-00AC/DC CONVERTER 60V 12V 800W |
3,299 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 2 | 85 ~ 264 VAC, 120 ~ 300 VDC | 60V | 12V | - | - | - | - | 6 A | 17 A | - | - | - | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-2E-1O-1Q-00AC/DC CONVERTER 5V 18V 24V 800W |
3,093 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 3 | 85 ~ 264 VAC, 120 ~ 300 VDC | 5V | 18V | 24V | - | - | - | 60 A | 11 A | 8.5 A | - | - | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-1E-1H-1L-1O-1Q-00ACDC CNVT 5V 6V 12V 18V 24V 800W |
3,571 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 5 | 85 ~ 264 VAC, 120 ~ 300 VDC | 5V | 6V | 12V | 18V | 24V | - | 35 A | 23 A | 17 A | 11 A | 8.5 A | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote Sense, Standby Output, Universal Input | Chassis Mount | 11.00" L x 5.00" W x 2.50" H (279.4mm x 127.0mm x 63.5mm) |
|
MP6-2E-2V-1Q-01AC/DC CONVERTER 5V 42V 24V 800W |
3,576 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 3 | 85 ~ 264 VAC, 120 ~ 300 VDC | 5V | 42V | 24V | - | - | - | 60 A | 7.5 A | 8.5 A | - | - | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-3F-1E-4LL-00AC/DC CNVRTR 5.2V 5V 2X12V 800W |
2,167 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 4 | 85 ~ 264 VAC, 120 ~ 300 VDC | 5.2V | 5V | 12V | 12V | - | - | 115 A | 35 A | 10 A | 4 A | - | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-1E-1L-1R-1Q-4NN-01AC/DC CNVT 5V 12V 28V 24V 2X15V |
4,110 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 6 | 85 ~ 264 VAC, 120 ~ 300 VDC | 5V | 12V | 28V | 24V | 15V | 15V | 35 A | 17 A | 6.7 A | 8.5 A | 8 A | 4 A | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-3S-2O-00AC/DC CONVERTER 30V 18V 800W |
3,045 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 2 | 85 ~ 264 VAC, 120 ~ 300 VDC | 30V | 18V | - | - | - | - | 20 A | 19 A | - | - | - | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-2R-2R-03AC/DC CONVERTER 2X28V 800W |
3,895 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 2 | 85 ~ 264 VAC, 120 ~ 300 VDC | 28V | 28V | - | - | - | - | 12.8 A | 12.8 A | - | - | - | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-2R-1E-1N-00AC/DC CONVERTER 28V 5V 15V 800W |
2,340 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 3 | 85 ~ 264 VAC, 120 ~ 300 VDC | 28V | 5V | 15V | - | - | - | 12.8 A | 35 A | 14 A | - | - | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-2L-1D-1E-4LL-00ACDC CNVT 12V 3.3V 5V 2X12V 800W |
4,017 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 5 | 85 ~ 264 VAC, 120 ~ 300 VDC | 12V | 3.3V | 5V | 12V | 12V | - | 30 A | 35 A | 35 A | 10 A | 4 A | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | 11.00" L x 5.00" W x 2.50" H (279.4mm x 127.0mm x 63.5mm) |
|
MP6-3Q-1F-0MAC/DC CONVERTER 24V 5.2V 800W |
2,062 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 2 | 85 ~ 264 VAC, 120 ~ 300 VDC | 24V | 5.2V | - | - | - | - | 23.5 A | 35 A | - | - | - | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-2Q-1E-4EE-NNN-0NAC/DC CNVT 24V 3X5V 2X15V 800W |
2,261 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 7 | 85 ~ 264 VAC, 120 ~ 300 VDC | 24V | 5V | 5V | 5V | 15V | 15V | 15 A | 35 A | 10 A | 10 A | 1 A | 1 A | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-3Q-1L-00AC/DC CONVERTER 24V 12V 800W |
3,121 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 2 | 85 ~ 264 VAC, 120 ~ 300 VDC | 24V | 12V | - | - | - | - | 23.5 A | 17 A | - | - | - | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-3L-2I-05AC/DC CONVERTER 12V 8V 800W |
3,820 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 2 | 85 ~ 264 VAC, 120 ~ 300 VDC | 12V | 8V | - | - | - | - | 50 A | 36 A | - | - | - | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-3Q-1L-0MAC/DC CONVERTER 24V 12V 800W |
4,737 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 2 | 85 ~ 264 VAC, 120 ~ 300 VDC | 24V | 12V | - | - | - | - | 23.5 A | 17 A | - | - | - | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-1Q-1V-4LE-00AC/DC CNVRTR 24V 42V 12V 5V 800W |
4,222 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 4 | 85 ~ 264 VAC, 120 ~ 300 VDC | 24V | 42V | 12V | 5V | - | - | 8.5 A | 4.2 A | 10 A | 10 A | - | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |
|
MP6-3E-2E-0PAC/DC CONVERTER 2X5V 800W |
4,902 |
|
![]() Tabla de datos |
MP6 (800W) | Bulk | Obsolete | Enclosed | 2 | 85 ~ 264 VAC, 120 ~ 300 VDC | 5V | 5V | - | - | - | - | 120 A | 60 A | - | - | - | - | 800W | ITE (Commercial), Medical | - | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | - |