Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo | Número de salidas | Voltaje - Entrada | Voltaje - Salida 1 | Voltaje - Salida 2 | Voltaje - Salida 3 | Voltaje - Salida 4 | Voltaje - Salida 5 | Voltaje - Salida 6 | Corriente - Salida 1 | Corriente - Salida 2 | Corriente - Salida 3 | Corriente - Salida 4 | Corriente - Salida 5 | Corriente - Salida 6 | Potencia (vatios) | Aplicaciones | Voltaje - Aislamiento | Temperatura de funcionamiento | Características | Tipo de montaje | Tamaño/Dimensión |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
NMP1K2-CKECCH-04AC/DC CNVT 5V 48V 12V 5V 24V |
3,193 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 12V | 5V | 24V | - | 36 A | 5 A | 20 A | 72 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKECCK-04AC/DC CNVT 5V 48V 12V 5V 48V |
4,020 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 12V | 5V | 48V | - | 36 A | 5 A | 20 A | 72 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKEEEC-04AC/DC CNVT 5V 48V 2X12V 5V 1200W |
2,521 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 12V | 12V | 5V | - | 36 A | 5 A | 20 A | 40 A | 36 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKEEEE-04AC/DC CNVT 5V 48V 3X12V 1200W |
4,548 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 12V | 12V | 12V | - | 36 A | 5 A | 20 A | 40 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKEEEH-04ACDC CNVT 5V 48V 2X12V 24V 1200W |
4,175 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 12V | 12V | 24V | - | 36 A | 5 A | 20 A | 40 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKEEEK-04ACDC CNVT 5V 48V 2X12V 48V 1200W |
2,231 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 12V | 12V | 48V | - | 36 A | 5 A | 20 A | 40 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKEHHC-04AC/DC CNVT 5V 48V 12V 24V 5V |
2,632 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 12V | 24V | 5V | - | 36 A | 5 A | 20 A | 20 A | 36 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKEHHE-04AC/DC CNVT 5V 48V 12V 24V 12V |
4,467 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 12V | 24V | 12V | - | 36 A | 5 A | 20 A | 20 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKEHHH-04ACDC CNVT 5V 48V 12V 2X24V 1200W |
3,438 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 12V | 24V | 24V | - | 36 A | 5 A | 20 A | 20 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKEHHK-04AC/DC CNVT 5V 48V 12V 24V 48V |
4,790 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 12V | 24V | 48V | - | 36 A | 5 A | 20 A | 20 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKEKKC-04AC/DC CNVT 5V 48V 12V 48V 5V |
2,633 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 12V | 48V | 5V | - | 36 A | 5 A | 20 A | 10 A | 36 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKEKKE-04AC/DC CNVT 5V 48V 12V 48V 12V |
2,798 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 12V | 48V | 12V | - | 36 A | 5 A | 20 A | 10 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKEKKH-04AC/DC CNVT 5V 48V 12V 48V 24V |
4,090 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 12V | 48V | 24V | - | 36 A | 5 A | 20 A | 10 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKEKKK-04ACDC CNVT 5V 48V 12V 2X48V 1200W |
4,054 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 12V | 48V | 48V | - | 36 A | 5 A | 20 A | 10 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKHCCC-04AC/DC CNVT 5V 48V 24V 2X5V 1200W |
3,003 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 5V | 5V | - | 36 A | 5 A | 10 A | 72 A | 36 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKHCCE-04AC/DC CNVT 5V 48V 24V 5V 12V |
3,851 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 5V | 12V | - | 36 A | 5 A | 10 A | 72 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKHCCH-04AC/DC CNVT 5V 48V 24V 5V 24V |
2,244 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 5V | 24V | - | 36 A | 5 A | 10 A | 72 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKHCCK-04AC/DC CNVT 5V 48V 24V 5V 48V |
3,671 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 5V | 48V | - | 36 A | 5 A | 10 A | 72 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKHEEC-04AC/DC CNVT 5V 48V 24V 12V 5V |
3,619 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 12V | 5V | - | 36 A | 5 A | 10 A | 40 A | 36 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKHEEE-04ACDC CNVT 5V 48V 24V 2X12V 1200W |
2,084 |
|
![]() Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 12V | 12V | - | 36 A | 5 A | 10 A | 40 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |