| Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo | Número de salidas | Voltaje - Entrada | Voltaje - Salida 1 | Voltaje - Salida 2 | Voltaje - Salida 3 | Voltaje - Salida 4 | Voltaje - Salida 5 | Voltaje - Salida 6 | Corriente - Salida 1 | Corriente - Salida 2 | Corriente - Salida 3 | Corriente - Salida 4 | Corriente - Salida 5 | Corriente - Salida 6 | Potencia (vatios) | Aplicaciones | Voltaje - Aislamiento | Temperatura de funcionamiento | Características | Tipo de montaje | Tamaño/Dimensión |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
NMP1K2-CCEKHH-01ACDC CNVT 5V 12V 48V 2X24V 1200W |
3,441 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 12V | 48V | 24V | 24V | - | 72 A | 20 A | 5 A | 10 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCEKHK-01AC/DC CNVT 5V 12V 48V 24V 48V |
3,280 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 12V | 48V | 24V | 48V | - | 72 A | 20 A | 5 A | 10 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCEKKC-01AC/DC CNVT 5V 12V 2X48V 5V 1200W |
4,076 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 12V | 48V | 48V | 5V | - | 72 A | 20 A | 5 A | 5 A | 36 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCEKKE-01ACDC CNVT 5V 12V 2X48V 12V 1200W |
2,539 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 12V | 48V | 48V | 12V | - | 72 A | 20 A | 5 A | 5 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCEKKH-01ACDC CNVT 5V 12V 2X48V 24V 1200W |
4,469 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 12V | 48V | 48V | 24V | - | 72 A | 20 A | 5 A | 5 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCEKKK-01AC/DC CNVT 5V 12V 3X48V 1200W |
3,724 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 12V | 48V | 48V | 48V | - | 72 A | 20 A | 5 A | 5 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCHCCC-01AC/DC CNVT 5V 24V 3X5V 1140W |
3,216 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 24V | 5V | 5V | 5V | - | 72 A | 10 A | 36 A | 36 A | 36 A | - | 1140W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCHCCE-01AC/DC CNVT 5V 24V 2X5V 12V 1200W |
2,905 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 24V | 5V | 5V | 12V | - | 72 A | 10 A | 36 A | 36 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCHCCH-01AC/DC CNVT 5V 24V 2X5V 24V 1200W |
2,881 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 24V | 5V | 5V | 24V | - | 72 A | 10 A | 36 A | 36 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCHCCK-01AC/DC CNVT 5V 24V 2X5V 48V 1200W |
3,691 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 24V | 5V | 5V | 48V | - | 72 A | 10 A | 36 A | 36 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCHCEC-01ACDC CNVT 5V 24V 5V 12V 5V 1200W |
4,811 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 24V | 5V | 12V | 5V | - | 72 A | 10 A | 36 A | 20 A | 36 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCHCEE-01AC/DC CNVT 5V 24V 5V 2X12V 1200W |
4,980 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 24V | 5V | 12V | 12V | - | 72 A | 10 A | 36 A | 20 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCHCEH-01AC/DC CNVT 5V 24V 5V 12V 24V |
2,465 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 24V | 5V | 12V | 24V | - | 72 A | 10 A | 36 A | 20 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCHCEK-01AC/DC CNVT 5V 24V 5V 12V 48V |
4,390 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 24V | 5V | 12V | 48V | - | 72 A | 10 A | 36 A | 20 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCHCHC-01ACDC CNVT 5V 24V 5V 24V 5V 1200W |
3,553 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 24V | 5V | 24V | 5V | - | 72 A | 10 A | 36 A | 10 A | 36 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCHCHE-01AC/DC CNVT 5V 24V 5V 24V 12V |
2,595 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 24V | 5V | 24V | 12V | - | 72 A | 10 A | 36 A | 10 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCHCHH-01AC/DC CNVT 5V 24V 5V 2X24V 1200W |
3,318 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 24V | 5V | 24V | 24V | - | 72 A | 10 A | 36 A | 10 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCHCHK-01AC/DC CNVT 5V 24V 5V 24V 48V |
3,802 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 24V | 5V | 24V | 48V | - | 72 A | 10 A | 36 A | 10 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCHCKC-01ACDC CNVT 5V 24V 5V 48V 5V 1200W |
4,057 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 24V | 5V | 48V | 5V | - | 72 A | 10 A | 36 A | 5 A | 36 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-CCHCKE-01AC/DC CNVT 5V 24V 5V 48V 12V |
3,879 |
|
Tabla de datos |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 24V | 5V | 48V | 12V | - | 72 A | 10 A | 36 A | 5 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |