Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo | Número de salidas | Voltaje - Entrada | Voltaje - Salida 1 | Voltaje - Salida 2 | Voltaje - Salida 3 | Voltaje - Salida 4 | Voltaje - Salida 5 | Voltaje - Salida 6 | Corriente - Salida 1 | Corriente - Salida 2 | Corriente - Salida 3 | Corriente - Salida 4 | Corriente - Salida 5 | Corriente - Salida 6 | Potencia (vatios) | Aplicaciones | Voltaje - Aislamiento | Temperatura de funcionamiento | Características | Tipo de montaje | Tamaño/Dimensión |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CUS400M-36/UAC/DC CONVERTER 36V 250W TDK-Lambda |
0 |
|
![]() Tabla de datos |
CUS400M (400W) | Box | Active | Open Frame | 1 | 85 ~ 264 VAC | 36V | - | - | - | - | - | 6.94 A | - | - | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote Sense, Universal Input | Chassis Mount | 5.59" L x 3.54" W x 1.61" H (142.0mm x 90.0mm x 41.0mm) |
![]() |
CUS400M-48/UAC/DC CONVERTER 48V 250W TDK-Lambda |
0 |
|
![]() Tabla de datos |
CUS400M (400W) | Box | Active | Open Frame | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 5.21 A | - | - | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote Sense, Universal Input | Chassis Mount | 5.59" L x 3.54" W x 1.61" H (142.0mm x 90.0mm x 41.0mm) |
![]() |
CUS600M1-32AC/DC CONVERTER 32V 400W TDK-Lambda |
0 |
|
![]() Tabla de datos |
CUS600M (600W) | Box | Active | Open Frame | 1 | 85 ~ 265 VAC | 32V | - | - | - | - | - | 12.5 A | - | - | - | - | - | 400W (602W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.46" H (127.0mm x 76.2mm x 37.1mm) |
![]() |
CUS600M1-28AC/DC CONVERTER 28V 400W TDK-Lambda |
0 |
|
![]() Tabla de datos |
CUS600M (600W) | Box | Active | Open Frame | 1 | 85 ~ 265 VAC | 28V | - | - | - | - | - | 14.3 A | - | - | - | - | - | 400W (602W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.46" H (127.0mm x 76.2mm x 37.1mm) |
![]() |
CUS600M1-36AC/DC CONVERTER 36V 400W TDK-Lambda |
0 |
|
![]() Tabla de datos |
CUS600M (600W) | Box | Active | Open Frame | 1 | 85 ~ 265 VAC | 36V | - | - | - | - | - | 11.1 A | - | - | - | - | - | 400W (601W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.46" H (127.0mm x 76.2mm x 37.1mm) |
![]() |
SWT100-522AC/DC CONVERTER 5V +/-12V 100W TDK-Lambda |
0 |
|
![]() Tabla de datos |
SWT (100W) | Bulk | Obsolete | Open Frame | 3 | 85 ~ 265 VAC | 5V | 12V | -12V | - | - | - | 8 A | 4 A | 800 mA | - | - | - | 100W | ITE (Commercial) | 3 kV | 0°C ~ 50°C | DC Input Capable, Universal Input | Chassis Mount | 7.75" L x 4.25" W x 1.77" H (196.9mm x 108.0mm x 45.0mm) |
![]() |
SWT100-525AC/DC CONVERTER 5V 12V -5V 100W TDK-Lambda |
0 |
|
![]() Tabla de datos |
SWT (100W) | Bulk | Obsolete | Open Frame | 3 | 85 ~ 265 VAC | 5V | 12V | -5V | - | - | - | 8 A | 4 A | 800 mA | - | - | - | 100W | ITE (Commercial) | 3 kV | 0°C ~ 50°C | DC Input Capable, Universal Input | Chassis Mount | 7.75" L x 4.25" W x 1.77" H (196.9mm x 108.0mm x 45.0mm) |
![]() |
SWT100-5FFAC/DC CONVERTER 5V +/-15V 100W TDK-Lambda |
0 |
|
![]() Tabla de datos |
SWT (100W) | Bulk | Obsolete | Open Frame | 3 | 85 ~ 265 VAC | 5V | 15V | -15V | - | - | - | 8 A | 3 A | 800 mA | - | - | - | 100W | ITE (Commercial) | 3 kV | 0°C ~ 50°C | DC Input Capable, Universal Input | Chassis Mount | 7.75" L x 4.25" W x 1.77" H (196.9mm x 108.0mm x 45.0mm) |
![]() |
CUS400M-48/AAC/DC CONVERTER 48V 250W TDK-Lambda |
0 |
|
![]() Tabla de datos |
CUS400M (400W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 5.21 A | - | - | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote Sense, Universal Input | Chassis Mount | 5.59" L x 3.54" W x 1.67" H (142.0mm x 90.0mm x 42.5mm) |
![]() |
CUS400M-36/AAC/DC CONVERTER 36V 250W TDK-Lambda |
0 |
|
![]() Tabla de datos |
CUS400M (400W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 36V | - | - | - | - | - | 6.94 A | - | - | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote Sense, Universal Input | Chassis Mount | 5.59" L x 3.54" W x 1.67" H (142.0mm x 90.0mm x 42.5mm) |