Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo | Número de salidas | Voltaje - Entrada | Voltaje - Salida 1 | Voltaje - Salida 2 | Voltaje - Salida 3 | Voltaje - Salida 4 | Voltaje - Salida 5 | Voltaje - Salida 6 | Corriente - Salida 1 | Corriente - Salida 2 | Corriente - Salida 3 | Corriente - Salida 4 | Corriente - Salida 5 | Corriente - Salida 6 | Potencia (vatios) | Aplicaciones | Voltaje - Aislamiento | Temperatura de funcionamiento | Características | Tipo de montaje | Tamaño/Dimensión |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
VMS-160-5AC/DC CONVERTER 5V 70W |
3,478 |
|
![]() Tabla de datos |
VMS-160 (160W) | Bulk | Active | Open Frame | 1 | 85 ~ 264 VAC, 125 ~ 373 VDC | 5V | - | - | - | - | - | 14 A | - | - | - | - | - | 70W (100W Forced Air) | Medical | 5.656 kV | -25°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 0.85" H (101.6mm x 50.8mm x 21.6mm) |
![]() |
VMS-160-24AC/DC CONVERTER 24V 100W |
2,910 |
|
![]() Tabla de datos |
VMS-160 (160W) | Bulk | Active | Open Frame | 1 | 85 ~ 264 VAC, 125 ~ 373 VDC | 24V | - | - | - | - | - | 4.17 A | - | - | - | - | - | 100W (160W Forced Air) | Medical | 5.656 kV | -25°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 0.85" H (101.6mm x 50.8mm x 21.6mm) |
![]() |
400133-02-1AC/DC CONVERTER 24V 12V 173W |
27 |
|
![]() Tabla de datos |
XR160 (160W) | Bulk | Active | Open Frame | 2 | - | 24V | 12V | - | - | - | - | 6.7 A | 1 A | - | - | - | - | 173W | ITE (Commercial) | - | -25°C ~ 70°C (With Derating) | DC Input Capable, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.32" H (127.0mm x 76.2mm x 33.6mm) |
![]() |
1010100CHCOSRW-45-1004 CHCO |
50 |
|
![]() Tabla de datos |
SRW-45 (45W) | Box | Not For New Designs | Enclosed | 1 | 100 ~ 240 VAC | 24V | - | - | - | - | - | 2 A | - | - | - | - | - | 45W | Industrial, ITE (Commercial) | - | 0°C ~ 50°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 5.15" L x 3.25" W x 1.56" H (130.8mm x 82.6mm x 39.6mm) |
![]() |
1010098CHCOSRW-45-1002 CHCO |
50 |
|
![]() Tabla de datos |
SRW-45 (45W) | Box | Not For New Designs | Enclosed | 1 | 100 ~ 240 VAC | 12V | - | - | - | - | - | 4 A | - | - | - | - | - | 45W | Industrial, ITE (Commercial) | - | 0°C ~ 50°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 5.15" L x 3.25" W x 1.56" H (130.8mm x 82.6mm x 39.6mm) |
![]() |
1010099CHCOSRW-45-1003 CHCO |
50 |
|
![]() Tabla de datos |
SRW-45 (45W) | Box | Not For New Designs | Enclosed | 1 | 100 ~ 240 VAC | 15V | - | - | - | - | - | 3 A | - | - | - | - | - | 45W | Industrial, ITE (Commercial) | - | 0°C ~ 50°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 5.15" L x 3.25" W x 1.56" H (130.8mm x 82.6mm x 39.6mm) |
![]() |
1010097CHCOSRW-45-1001 CHCO |
50 |
|
![]() Tabla de datos |
SRW-45 (45W) | Box | Not For New Designs | Enclosed | 1 | 100 ~ 240 VAC | 5V | - | - | - | - | - | 9 A | - | - | - | - | - | 45W | Industrial, ITE (Commercial) | - | 0°C ~ 50°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 5.15" L x 3.25" W x 1.56" H (130.8mm x 82.6mm x 39.6mm) |
![]() |
1011385CHCOGRN-80-3001 OVP CHCO |
50 |
|
![]() Tabla de datos |
GRN-80 (80W) | Box | Active | Enclosed | 3 | 85 ~ 264 VAC | 5V | 12V | -12V | - | - | - | 8 A | 2 A | 2 A | - | - | - | 88W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.25" L x 3.25" W x 1.28" H (133.4mm x 82.6mm x 32.5mm) |
![]() |
1011386CHCOGRN-80-3002 OVP CHCO |
50 |
|
![]() Tabla de datos |
GRN-80 (80W) | Box | Active | Enclosed | 3 | 85 ~ 264 VAC | 5V | 15V | -15V | - | - | - | 8 A | 2 A | 2 A | - | - | - | 80W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.25" L x 3.25" W x 1.28" H (133.4mm x 82.6mm x 32.5mm) |
![]() |
1011372GRN-110-4002 OVP |
50 |
|
![]() Tabla de datos |
GRN-110 (110W) | Box | Active | Open Frame | 4 | 85 ~ 264 VAC | 5V | -5V | 12V | -12V | - | - | 10 A | 5 A | 2 A | 2 A | - | - | 110W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.06" H (127.0mm x 76.2mm x 26.9mm) |
![]() |
1011371GRN-110-4001 OVP |
50 |
|
![]() Tabla de datos |
GRN-110 (110W) | Box | Active | Open Frame | 4 | 85 ~ 264 VAC | 3.3V | 5V | 12V | -12V | - | - | 10 A | 5 A | 2 A | 2 A | - | - | 110W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.06" H (127.0mm x 76.2mm x 26.9mm) |
![]() |
1011243CHGRN-110-4003 CH |
50 |
|
![]() Tabla de datos |
GRN-110 (110W) | Box | Active | Chassis | 4 | 85 ~ 264 VAC | 5V | 24V | 12V | -12V | - | - | 10 A | 2 A | 2 A | 2 A | - | - | 110W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) |
![]() |
1011241CHGRN-110-4001 CH |
50 |
|
![]() Tabla de datos |
GRN-110 (110W) | Box | Active | Chassis | 4 | 85 ~ 264 VAC | 3.3V | 5V | 12V | -12V | - | - | 10 A | 5 A | 2 A | 2 A | - | - | 110W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) |
![]() |
1011244CHGRN-110-4004 CH |
50 |
|
![]() Tabla de datos |
GRN-110 (110W) | Box | Active | Chassis | 4 | 85 ~ 264 VAC | 5V | 24V | 15V | -15V | - | - | 10 A | 2 A | 2 A | 2 A | - | - | 110W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) |
![]() |
1011242CHGRN-110-4002 CH |
50 |
|
![]() Tabla de datos |
GRN-110 (110W) | Box | Active | Chassis | 4 | 85 ~ 264 VAC | 5V | -5V | 12V | -12V | - | - | 10 A | 5 A | 2 A | 2 A | - | - | 110W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) |
![]() |
1011373GRN-110-4003 OVP |
31 |
|
![]() Tabla de datos |
GRN-110 (110W) | Box | Active | Open Frame | 4 | 85 ~ 264 VAC | 5V | 24V | 12V | -12V | - | - | 10 A | 2 A | 2 A | 2 A | - | - | 110W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.06" H (127.0mm x 76.2mm x 26.9mm) |
![]() |
MINT1175A4806K01AC/DC CONVERTER 48V 120W |
3 |
|
![]() Tabla de datos |
MINT1175 (175W) | Bulk | Obsolete | Open Frame | 1 | 90 ~ 264 VAC | 48V | - | - | - | - | - | 2 A | - | - | - | - | - | 120W (175W Forced Air) | Medical | 4 kV | -10°C ~ 70°C (With Derating) | Adjustable Output, Remote On/Off, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.30" H (101.6mm x 50.8mm x 33.0mm) |
![]() |
MINT1175A5606K01AC/DC CONVERTER 56V 120W |
2,113 |
|
![]() Tabla de datos |
MINT1175 (175W) | Bulk | Active | Open Frame | 1 | 90 ~ 264 VAC | 56V | - | - | - | - | - | 2.1 A | - | - | - | - | - | 120W (175W Forced Air) | Medical | 4 kV | -10°C ~ 70°C (With Derating) | Adjustable Output, Remote On/Off, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.30" H (101.6mm x 50.8mm x 33.0mm) |
![]() |
MINT1175A2406K01AC/DC CONVERTER 24V 120W |
2,838 |
|
![]() Tabla de datos |
MINT1175 (175W) | Bulk | Obsolete | Open Frame | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 5 A | - | - | - | - | - | 120W (175W Forced Air) | Medical | 4 kV | -10°C ~ 70°C (With Derating) | Adjustable Output, Remote On/Off, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.30" H (101.6mm x 50.8mm x 33.0mm) |
![]() |
VOF-100-48AC/DC CONVERTER 48V 100W |
2,851 |
|
![]() Tabla de datos |
VOF-100 (100W) | Bulk | Obsolete | Open Frame | 1 | 90 ~ 277 VAC | 48V | - | - | - | - | - | 2.1 A | - | - | - | - | - | 100W | ITE (Commercial) | 3 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.32" H (101.6mm x 50.8mm x 33.6mm) |