Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Embalaje | Estado del producto | Tipo | Número de salidas | Voltaje - Entrada | Voltaje - Salida 1 | Voltaje - Salida 2 | Voltaje - Salida 3 | Voltaje - Salida 4 | Voltaje - Salida 5 | Voltaje - Salida 6 | Corriente - Salida 1 | Corriente - Salida 2 | Corriente - Salida 3 | Corriente - Salida 4 | Corriente - Salida 5 | Corriente - Salida 6 | Potencia (vatios) | Aplicaciones | Voltaje - Aislamiento | Temperatura de funcionamiento | Características | Tipo de montaje | Tamaño/Dimensión |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
PBA150F-5-ENAC/DC CONVERTER 5V |
2,937 |
|
![]() Tabla de datos |
PBA (150W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 5V | - | - | - | - | - | 30 A | - | - | - | - | - | - | ITE (Commercial) | 3 kV | -10°C ~ 71°C (With Derating) | - | Chassis Mount | 6.61" L x 1.34" W x 3.66" H (167.9mm x 34.0mm x 93.0mm) |
![]() |
PBA150F-5-GNAC/DC CONVERTER 5V |
3,564 |
|
![]() Tabla de datos |
PBA (150W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 5V | - | - | - | - | - | 30 A | - | - | - | - | - | - | ITE (Commercial) | 3 kV | -10°C ~ 71°C (With Derating) | - | Chassis Mount | 6.61" L x 1.34" W x 3.66" H (167.9mm x 34.0mm x 93.0mm) |
![]() |
PBA150F-9-ENAC/DC CONVERTER 9V |
4,006 |
|
![]() Tabla de datos |
PBA (150W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 9V | - | - | - | - | - | 16.7 A | - | - | - | - | - | - | ITE (Commercial) | 3 kV | -10°C ~ 71°C (With Derating) | - | Chassis Mount | 6.61" L x 1.34" W x 3.66" H (167.9mm x 34.0mm x 93.0mm) |
![]() |
PBA150F-9-GNAC/DC CONVERTER 9V |
4,339 |
|
![]() Tabla de datos |
PBA (150W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 9V | - | - | - | - | - | 16.7 A | - | - | - | - | - | - | ITE (Commercial) | 3 kV | -10°C ~ 71°C (With Derating) | - | Chassis Mount | 6.61" L x 1.34" W x 3.66" H (167.9mm x 34.0mm x 93.0mm) |
![]() |
FXA350048AAC/DC CONVERTER 48V 250W |
4,678 |
|
![]() Tabla de datos |
FXA350 (350W) | Bulk | Active | Open Frame | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 5.3 A | - | - | - | - | - | 250W (350W Forced Air) | ITE (Commercial) | - | 0°C ~ 70°C (With Derating) | PFC, Remote Sense, Standby Output, Universal Input | Chassis Mount | 8.00" L x 5.00" W x 1.50" H (203.2mm x 127.0mm x 38.1mm) |
|
CSU550AP-3AC/DC CONVERTER 12V 12V 550W |
2,368 |
|
![]() Tabla de datos |
CSU550AP (550W) | Bulk | Active | Front End | 2 | 90 ~ 264 VAC | 12V | 12V | - | - | - | - | 45 A | 2.5 A | - | - | - | - | 550W | ITE (Commercial) | - | 0°C ~ 50°C (With Derating) | DC Input Capable, Hot Swappable, Load Sharing, PMBus™, Standby Output, Universal Input | Rack Mount | 7.28" L x 2.89" W x 1.57" H (185.0mm x 73.5mm x 40.0mm) |
|
CSU550AP-3-001AC/DC CONVERTER 12V 12V 550W |
4,813 |
|
![]() Tabla de datos |
CSU550AP (550W) | Bulk | Active | Front End | 2 | 90 ~ 264 VAC | 12V | 12V | - | - | - | - | 45 A | 2.5 A | - | - | - | - | 550W | ITE (Commercial) | - | 0°C ~ 50°C (With Derating) | DC Input Capable, Hot Swappable, Load Sharing, PMBus™, Standby Output, Universal Input | Rack Mount | 7.28" L x 2.89" W x 1.57" H (185.0mm x 73.5mm x 40.0mm) |
![]() |
RACM100-12S/OFAC/DC CONVERTER 12V 100W |
2,957 |
|
![]() Tabla de datos |
MEDLINE RACM100 (100W) | Box | Active | Open Frame | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 8.34 A | - | - | - | - | - | 100W | Medical | 4 kV | -25°C ~ 85°C (With Derating) | Adjustable Output, DC Input Capable, PFC, Universal Input | Chassis Mount | 3.60" L x 2.44" W x 1.54" H (91.4mm x 62.0mm x 39.2mm) |
![]() |
RACM100-15S/OFAC/DC CONVERTER 15V 100W |
4,346 |
|
![]() Tabla de datos |
MEDLINE RACM100 (100W) | Box | Active | Open Frame | 1 | 85 ~ 264 VAC | 15V | - | - | - | - | - | 6.67 A | - | - | - | - | - | 100W | Medical | 4 kV | -25°C ~ 85°C (With Derating) | Adjustable Output, DC Input Capable, PFC, Universal Input | Chassis Mount | 3.60" L x 2.44" W x 1.54" H (91.4mm x 62.0mm x 39.2mm) |
![]() |
RACM100-48S/OFAC/DC CONVERTER 48V 100W |
4,858 |
|
![]() Tabla de datos |
MEDLINE RACM100 (100W) | Box | Active | Open Frame | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 2.09 A | - | - | - | - | - | 100W | Medical | 4 kV | -25°C ~ 85°C (With Derating) | Adjustable Output, DC Input Capable, PFC, Universal Input | Chassis Mount | 3.60" L x 2.44" W x 1.54" H (91.4mm x 62.0mm x 39.2mm) |
![]() |
SLS-24-024TAC/DC CONVERTER 24V 58W |
3,252 |
|
![]() Tabla de datos |
Silver Line | Bulk | Obsolete | Open Frame | 1 | 100 ~ 240 VAC | 24V | - | - | - | - | - | 2.4 A | - | - | - | - | - | 58W | ITE (Commercial) | - | 0°C ~ 50°C | Adjustable Output, Remote Sense | Chassis Mount | 5.62" L x 4.87" W x 1.28" H (142.7mm x 123.7mm x 32.5mm) |
![]() |
VGS-600-27AC/DC CONVERTER 27V 633W |
2,687 |
|
![]() Tabla de datos |
VGS-600 (600W) | Box | Not For New Designs | Enclosed | 1 | 80 ~ 277 VAC, 110 ~ 390 VDC | 27V | - | - | - | - | - | 22.3 A | - | - | - | - | - | 633W | ITE (Commercial) | 4 kV | -40°C ~ 70°C | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output | Chassis Mount | 7.90" L x 4.00" W x 1.60" H (200.6mm x 101.6mm x 40.6mm) |
![]() |
VGS-600-15AC/DC CONVERTER 15V 632W |
4,679 |
|
![]() Tabla de datos |
VGS-600 (600W) | Box | Not For New Designs | Enclosed | 1 | 80 ~ 277 VAC, 110 ~ 390 VDC | 15V | - | - | - | - | - | 40 A | - | - | - | - | - | 632W | ITE (Commercial) | 4 kV | -40°C ~ 70°C | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output | Chassis Mount | 7.90" L x 4.00" W x 1.60" H (200.6mm x 101.6mm x 40.6mm) |
![]() |
PBA150F-12-D10NAC/DC CONVERTER 12V |
4,332 |
|
![]() Tabla de datos |
PBA (150W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 13 A | - | - | - | - | - | - | ITE (Commercial) | 3 kV | -10°C ~ 71°C (With Derating) | - | Chassis Mount | 6.61" L x 1.34" W x 3.66" H (167.9mm x 34.0mm x 93.0mm) |
![]() |
PBA150F-15-D16NAC/DC CONVERTER 15V |
2,623 |
|
![]() Tabla de datos |
PBA (150W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 15V | - | - | - | - | - | 10 A | - | - | - | - | - | - | ITE (Commercial) | 3 kV | -10°C ~ 71°C (With Derating) | - | Chassis Mount | 6.61" L x 1.34" W x 3.66" H (167.9mm x 34.0mm x 93.0mm) |
![]() |
PBA150F-48-D40NAC/DC CONVERTER 48V |
4,123 |
|
![]() Tabla de datos |
PBA (150W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 3.3 A | - | - | - | - | - | - | ITE (Commercial) | 3 kV | -10°C ~ 71°C (With Derating) | - | Chassis Mount | 6.61" L x 1.34" W x 3.66" H (167.9mm x 34.0mm x 93.0mm) |
![]() |
CUS250M-18/UAC/DC CONVERTER 18V 250W |
4,743 |
|
![]() Tabla de datos |
CUS250M (250W) | Bulk | Active | Open Frame | 1 | 80 ~ 264 VAC | 18V | - | - | - | - | - | 13.88 A | - | - | - | - | - | 250W | Household Appliances, ITE (Commercial), Laboratory, Medical | 4 kV | -20°C ~ 85°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Universal Input | Chassis Mount | 4.69" L x 2.52" W x 1.56" H (119.2mm x 64.0mm x 39.5mm) |
![]() |
CUS250M-48/UAC/DC CONVERTER 48V 250W |
3,346 |
|
![]() Tabla de datos |
CUS250M (250W) | Bulk | Active | Open Frame | 1 | 80 ~ 264 VAC | 48V | - | - | - | - | - | 5.2 A | - | - | - | - | - | 250W | Household Appliances, ITE (Commercial), Laboratory, Medical | 4 kV | -20°C ~ 85°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Universal Input | Chassis Mount | 4.69" L x 2.52" W x 1.56" H (119.2mm x 64.0mm x 39.5mm) |
![]() |
CUS250M-36/UAC/DC CONVERTER 36V 250W |
3,503 |
|
![]() Tabla de datos |
CUS250M (250W) | Bulk | Active | Open Frame | 1 | 80 ~ 264 VAC | 36V | - | - | - | - | - | 6.94 A | - | - | - | - | - | 250W | Household Appliances, ITE (Commercial), Laboratory, Medical | 4 kV | -20°C ~ 85°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Universal Input | Chassis Mount | 4.69" L x 2.52" W x 1.56" H (119.2mm x 64.0mm x 39.5mm) |
![]() |
CUS250M-28/UAC/DC CONVERTER 28V 250W |
2,475 |
|
![]() Tabla de datos |
CUS250M (250W) | Bulk | Active | Open Frame | 1 | 80 ~ 264 VAC | 28V | - | - | - | - | - | 8.92 A | - | - | - | - | - | 250W | Household Appliances, ITE (Commercial), Laboratory, Medical | 4 kV | -20°C ~ 85°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Universal Input | Chassis Mount | 4.69" L x 2.52" W x 1.56" H (119.2mm x 64.0mm x 39.5mm) |